Are you looking quote for part FSP350-60PLN? The Z Microsystems Inc-manufactured component (CAGE Code: 0XWT1) is documented under NSN 6130-01-526-3419 as Power Supply. For the fastest quote, please complete our RFQ form with details about FSP350-60PLN. We guarantee a response within 15 minutes.

ASAP Components provides the verified FSP350-60PLN, classified under INC 00740, FSG 61 Electric Wire and Power and Distribution Equipment, FSC 6130 Converters Electrical Nonrotating, NIIN 01-526-3419, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for FSP350-60PLN

“*” Required Fields Are Compulsory

NSN Information for Part Number FSP350-60PLN with NSN 6130-01-526-3419, 6130015263419

NSNFSCNIINCLSHazmatDEMILCancelled NSN
6130-01-526-3419

Item PartTypeName:

POWER SUPPLY

61300152634190NA
CIICHCCESDPMICCriticalityENAC
UAA0
Part NumberISCRNVCRNCCHCCMSDSSADC
04-91875523

Characteristics Data of NSN 6130-01-526-3419, 6130015263419

MRCCriteriaCharacteristic
APPAOutput Voltage Rating5.0 DC VOLTS NOMINAL 6TH POWER OUTPUT
ABHPOverall Length5.500 INCHES MINIMUM
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
AGAVEnd Item IdentificationOL-500/USQ
ABMKOverall Width5.900 INCHES MINIMUM
MRCDecoded RequirementClear Text Reply
CWGHOutput Current Rating2.0 DC AMPERES MAXIMUM 6TH POWER OUTPUT
CWGZRipple Voltage At Full Load100.0 MILLIVOLTS PEAK 4TH POWER OUTPUT
CWGZRipple Voltage At Full Load50.0 MILLIVOLTS PEAK 2ND POWER OUTPUT
CWGHOutput Current Rating0.3 DC AMPERES MAXIMUM 4TH POWER OUTPUT
CWGHOutput Current Rating0.3 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 28.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT
CWGHOutput Current Rating0.1 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 32.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT
CWGHOutput Current Rating0.8 DC AMPERES MAXIMUM 5TH POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating16.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT
APPAOutput Voltage Rating-12.0. DC VOLTS NOMINAL 5TH POWER OUTPUT
CWGZRipple Voltage At Full Load120.0 MILLIVOLTS PEAK 3RD POWER OUTPUT
CWGZRipple Voltage At Full Load120.0 MILLIVOLTS PEAK 5TH POWER OUTPUT
CWGZRipple Voltage At Full Load100.0 MILLIVOLTS PEAK 6TH POWER OUTPUT
CWGZRipple Voltage At Full Load50.0 MILLIVOLTS PEAK 1ST POWER OUTPUT
APNXInput Voltage Rating90.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
APPAOutput Voltage Rating3.3 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating-5.0. DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
ABKWOverall Height3.400 INCHES MINIMUM

Schedule B & Trade

End Use : 20000 Generators, accessories
Schedule B : 8504900080 (NAICS 334419) Static converter & inductor parts, nesoi
SITC : 77129 Parts of electric power machinery (other than rotating electric power generating machinery and equipment), and parts thereof

Identification

ADPE Represents items with no adp components
CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
ESD A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
HMIC N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL 9b-----
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: M - 85.0
NMFC: 062900 - Rectifiers noi/battery eliminators
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 595 - Transformer, (machinery and parts),(less than 35 feet)