Are you looking for a quote on part number WE-3996? If so, please fill out the form provided below. The national stock number is 5950013173101, and the part is manufactured by Wems Inc. Description is Transformer Power. The Cage Code for part number WE-3996 is 26543. Please enter as much detail as possible, this information will help us provide you the best quote for your needs. We will get back to you in just 15 minutes!
Part Number WE-3996 Specification |
|||
---|---|---|---|
Part Number : WE-3996 | Manufacturer : Wems Inc | NSN : 5950-01-317-3101 (5950013173101) | |
Item Name : Transformer Power | CAGE Code : 26543 | ||
Alternate P/N : WE3996 | |||
FSC CODE : 5950 Coils and Transformers |
“*” Symbols for mandatory fields
ASAP-Components.com, owned by ASAP Semiconductor is a leading distributor of obsolete national stock numbers. We are an, an AS9120B and ISO 9001:2015 company. We stock a vast inventory of over 10 million NSN parts which are sourced from over 5,000 manufacturers. All NSN parts such as WE-3996 are organized in 26 different categories with distinct supply codes.
A national stock number (NSN) part is distinguished by a specific number. This number indicates procurement, stocking, and storage of this part through the federal supply system. Part number WE-3996 possess the Federal Supply Group is FSC 5950 Coils and Transformers. This part and other NSN parts are an essential part of the defense and military supply chain.
Your quote request will be answered by a member of our experienced sales team. Feel free to call us on our toll-free number, +1-714-705-4780, we are available 24/7. You can also email your Bill of Materials (BOM) to sales@asap-components.com to expedite the purchasing process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-317-3101 Item Description: Transformer Power | 5950 | 013173101 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
We-3996 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.775 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.035 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 198.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.05 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 353.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.43 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 1.79 KILOVOLT-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 28.13 VOLTS-AMPERES SINGLE COMPONENT SINGLE TERTIARY |
CRMJ | WINDING POWER RATING | 59.73 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 13.72 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CWJS | WINDING OPERATING VOLTAGE | 18.10 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 27.15 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS; TERMINALS 23 AND 24 SPLIT FOR DUAL CONNECTION; TERTIARY WINDING TIED TO THE FOURTH SECONDARY WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 1 BUS (BAR) CONDUCTOR AND 22 PIN AND 2 RIBBON |
ADAQ | BODY LENGTH | 3.600 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT AND 1 TERTIARY SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 116.38 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.308 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.328 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM SINGLE GROUP AND 0.276 INCHES MAXIMUM SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 226.24 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 82577-H940081 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
Guaranteed on-time Delivery
Customized Database
Over 5100 Manufacturers
Complete Purchasing Solutions
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote