Are you looking quote for part 803-1385925-20? The Trola Dyne Inc-manufactured component (CAGE Code: 8W625) is documented under NSN 5930-01-519-7588 as Switch Toggle. For the fastest quote, please complete our RFQ form with details about 803-1385925-20. We guarantee a response within 15 minutes.
ASAP Components provides the verified 803-1385925-20, classified under INC 00184, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-519-7588, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-01-519-7588 Item PartTypeName: SWITCH,TOGGLE | 5930 | 015197588 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 803-1385925-20 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 2.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.100 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 0.600 INCHES NOMINAL |
| AFCG | SWITCH ACTUATOR QUANTITY | 1 |
| AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC |
| AGAV | END ITEM IDENTIFICATION | PANEL, AIR CONTROL ASSEMBLY |
| CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.000 AMPERES RESISTIVE AC |
| FEAT | SPECIAL FEATURES | SERIES E10; SPST; UP POSITION OFF, CENTER POSITION NONE, DOWN POSITION ON; LEVER 0.563 INCHES LONG; SCREW TERMINALS; DOWN POSITION HAS MOMENTARY CONTACTS, SPRING RETURN ACTION |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |