Are you looking quote for part PAC2G? The Thermo Eberline Llc-manufactured component (CAGE Code: 04596) is documented under NSN 6665-00-581-2227 as Radiacmeter. For the fastest quote, please complete our RFQ form with details about PAC2G. We guarantee a response within 15 minutes.
ASAP Components provides the verified PAC2G, classified under INC 07833, FSG 66 Instruments and Laboratory Equipment, FSC 6665 Hazard Detecting Instruments And Apparatus, NIIN 00-581-2227, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| FTLD | Functional Description | A PORTABLE BATTERY OPERATED GAS FLOW PROPORTIONAL INSTRUMENT DESIGNED FOR ALPHA DETECTING AND MEASURING |
| AMRM | Radiation Type And Function | ALPHA RAYS MEASURES |
| AMRX | Detecting Element Type | IONIZATION CHAMBER |
| NTRD | Entry Date | 70-04-01 |
| ABMK | Overall Width | 3.938 INCHES NOMINAL |
| FCLS | Functional Classification | AA-5.11 |
| MRC | Decoded Requirement | Clear Text Reply |
| RTSE | Relationship To Similar Equipment | SIMILAR TO PAC-2 RADIAC SET |
| ABKW | Overall Height | 9.750 INCHES NOMINAL |
| TMDN | Type/Model Designation | PAC-2GA |
| ADTV | Case Material | ALUMINUM |
| ABHP | Overall Length | 8.250 INCHES NOMINAL |
| RDAL | Reference Data And Literature | EBERLINE INST. CORP. COMMERCIAL DATA |
| ALSF | Internal Battery Accommodation | INCLUDED |
| AMKD | Indicator Type | COUNTER |
| End Use : 21600 | Laboratory testing instruments |
|---|---|
| Schedule B : 9022298000 (NAICS 334517) | Apparatus based on the use of alpha, beta or gamma radiations for other use, nesoi |
| SITC : 77422 | Apparatus based on the use of alpha, beta or gamma radiations, whether or not for medical, surgical, dental or veterinary uses, etc. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | P - 77.5 |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | D - Moderate sensitivity, category iii, aa&e, unclassified |
| TCC: | A - Radioactive substances, un class 7 (radioactive label) |
| WCC: | 653 - Musical instruments |