Are you looking quote for part 125021? The Systems West Inc-manufactured component (CAGE Code: 58558) is documented under NSN 5950-01-361-1399 as Transformer Power. For the fastest quote, please complete our RFQ form with details about 125021. We guarantee a response within 15 minutes.
ASAP Components provides the verified 125021, classified under INC 32496, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 01-361-1399, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-361-1399 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013611399 | P | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 125021 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ADAQ | BODY LENGTH | 3.200 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.200 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.000 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | OPEN |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MINIMUM SINGLE COMPONENT ALL SECONDARY AND 9.3 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 15.00 AC VOLTS MINIMUM SINGLE COMPONENT ALL PRIMARY AND 115.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
| CWJS | WINDING OPERATING VOLTAGE | 9.25 AC VOLTS MINIMUM SINGLE COMPONENT ALL SECONDARY AND 19.40 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |