Are you looking quote for part TDML120AL? The Ssac Inc-manufactured component (CAGE Code: 53010) is documented under NSN 5945-01-446-6906 as Relay Electromagnet. For the fastest quote, please complete our RFQ form with details about TDML120AL. We guarantee a response within 15 minutes.
ASAP Components provides the verified TDML120AL, classified under INC 32512, FSG 59 Electrical and Electronic Equipment Components, FSC 5945 Relays and Solenoids, NIIN 01-446-6906, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5945-01-446-6906 Item Description: RELAY,ELECTROMAGNETIC | 5945 | 014466906 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| TDML120AL | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| CRXH | TIME DELAY | 0.10 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 102.30 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ENERGIZING ELEMENT |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |