Are you looking quote for part 4506? The Sigma Instruments Inc-manufactured component (CAGE Code: 78277) is documented under NSN 6625-00-713-3941 as Test Set Relay. For the fastest quote, please complete our RFQ form with details about 4506. We guarantee a response within 15 minutes.
ASAP Components provides the verified 4506, classified under INC 03667, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 00-713-3941, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| AKVY | ACCESSORY CONTROLLING AGENCY | SIGMA INSTRUMENTS INC |
| AFHS | ACCESSORY COMPONENT QUANTITY | 1 |
| ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| AEAS | MAJOR COMPONENTS | CABLE |
| ABGL | WIDTH | 6.000 INCHES NOMINAL |
| SR-5 | MANUFACTURERS CODE | 78277 |
| HGTH | HEIGHT | 5.250 INCHES NOMINAL |
| ANNQ | MATERIAL AND LOCATION | FIBERGLASS HOUSING |
| AQXY | TEST TYPE FOR WHICH DESIGNED | TESTS SENSITIVITY,MEASURES BIAS,MEASURES BREAK TIME,TEST HIGH POTENTIAL BETWEEN CONTACT CIRCUITS AND RELAY COILS |
| ABRY | LENGTH | 19.000 INCHES NOMINAL |
| SR-5 | DESIGN CONTROL REFERENCE | 4506 |
| AQXZ | OPERATING TEST CAPABILITY | MILLIAMETER RANGE 5-0-5 MA DC BIAS 0 TO 25 PCT BREAK TIME 0 TO 25 PCT OF LINE FREQ HIGH POTENTIAL 500 V 60 CPS CURRENT LIMITED TO 1 MA |
| SR-5 | THE MANUFACTURERS DATA |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
| SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | V |
|---|---|
| Classification Control | U |
| MGMT_CTL | 7zte009 |
| Quantity per pack | No qup |
| Repariability | If condemned or uneconomically repairable, then dispose at intermediate level. |
| Shelf Life | N/A |
| SOS | Nrp |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | W - Rating variable |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |