Quote for 54LA12 Siemens Energy And Automation Inc Part with NSN 5930-01-259-3726

Part Number:  54LA12
NIIN:  12593726
Item Name :  switch sensitive
CAGE Code:  23826
FSC:  5930 Switches
INC Code:  00399
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-18-2026

Are you looking quote for part 54LA12? The Siemens Energy And Automation Inc-manufactured component (CAGE Code: 23826) is documented under NSN 5930-01-259-3726 as Switch Sensitive. For the fastest quote, please complete our RFQ form with details about 54LA12. We guarantee a response within 15 minutes.

ASAP Components provides the verified 54LA12, classified under INC 00399, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-259-3726, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 54LA12

“*” Required Fields Are Compulsory

NSN Information for Part Number 54LA12 with NSN 5930-01-259-3726, 5930012593726

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5930-01-259-3726

Item PartTypeName:

SWITCH,SENSITIVE

59300125937260P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
54LA12523

Characteristics Data of NSN 5930-01-259-3726, 5930012593726

MRCCriteriaCharacteristic
AAQLBODY STYLEHOLE MOUNTED
AFXEMAXIMUM VOLTAGE RATING IN VOLTS600.0 AC
AKNAINCLOSURE TYPEFULLY INCLOSED
CRLDNONPILE-UP CONTACT ARRANGEMENT2 TWO CIRCUIT,BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
CSJNSWITCH ACTUATING FORCE72.0 OUNCES NOMINAL
CXQQACTUATOR MOVEMENT20.0 PRETRAVEL DEGREES NOMINAL AND 30.0 OVERTRAVEL DEGREES NOMINAL AND 12.0 DIFFERENTIAL DEGREES NOMINAL
FEATSPECIAL FEATURESELECTRICAL ACCESS PORT

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536509050 (NAICS 335931) Switches, slide, for a voltage not exceeding 1, 000 v
SITC : 77255 Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL Sf9eh-n
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components

ASAP Semiconductor’s Certifications And Memberships



bottom to top