Are you looking quote for part 3TC2 20? The Sensata Technologies Inc-manufactured component (CAGE Code: 82647) is documented under NSN 5925-01-582-7364 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 3TC2 20. We guarantee a response within 15 minutes.
ASAP Components provides the verified 3TC2 20, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-582-7364, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-582-7364 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015827364 | P | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 3TC2-20 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKPX | Pole Quantity | 1 |
| AAQL | Body Style | SINGLE POLE TYPE |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SINGLE LOCATION |
| ABXD | Bushing Length | 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
| CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| ADAT | Body Width | 0.781 INCHES MAXIMUM |
| CPRQ | Reset Method | MANUAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 SINGLE LOCATION |
| CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
| MRC | Decoded Requirement | Clear Text Reply |
| ADTV | Case Material | PLASTIC |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
| THSD | Thread Series Designator | UNS |
| ADAQ | Body Length | 1.094 INCHES MAXIMUM |
| AJWX | Mounting Surface To Terminal End Distance | 1.343 INCHES MAXIMUM |
| CQJX | Nominal Thread Size | 0.438 INCHES |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.673 INCHES MINIMUM AND 0.735 INCHES MAXIMUM |
| CMLP | Thread Quantity Per Inch | 32 |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 35.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |