Quote for APL-211-5055-3 Sensata Technologies Inc Part with NSN 5925-01-212-0118

Part Number:  APL-211-5055-3
Alternate P/N:  APL21150553
Manufacturer:  sensata technologies inc
NIIN:  12120118
Item Name :  circuit breaker
CAGE Code:  81541
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-09-2026

Are you looking quote for part APL-211-5055-3? The Sensata Technologies Inc-manufactured component (CAGE Code: 81541) is documented under NSN 5925-01-212-0118 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about APL-211-5055-3. We guarantee a response within 15 minutes.

ASAP Components provides the verified APL-211-5055-3, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-212-0118, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for APL-211-5055-3

“*” Required Fields Are Compulsory

NSN Information for Part Number APL-211-5055-3 with NSN 5925-01-212-0118, 5925012120118

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-212-0118

Item PartTypeName:

CIRCUIT BREAKER

59250121201180P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
6010632-003593

Characteristics Data of NSN 5925-01-212-0118, 5925012120118

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.490 INCHES NOMINAL
ADATBODY WIDTH2.250 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.667 INCHES NOMINAL AND 1.940 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.150 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.475 INCHES NOMINAL
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC AND 25.0 AMPERES DC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 DC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS277.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS277.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC AND 5000.0 DC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS FIRST LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SECOND LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY THIRD LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP FIRST LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY8 THREADED STUD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC D
Classification Control U
MGMT_CTL Sf9eh-e
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top