Are you looking quote for part B4975? The Rowan Bmi Corp-manufactured component (CAGE Code: 15638) is documented under NSN 5925-00-173-7155 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about B4975. We guarantee a response within 15 minutes
ASAP Components provides the verified B4975, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 00-173-7155, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-173-7155 Item PartTypeName: CIRCUIT BREAKER | 5925 | 001737155 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
102-0011 | 1 | 1 | C |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.189 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.188 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.812 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.000 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 30.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 6000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND DUSTPROOF AND EXPLOSION PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CTJS | UNPACKAGED UNIT WEIGHT | 0.200 POUNDS NOMINAL |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-5809 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
End Use : 20005 | Electric apparatus |
---|---|
Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | U - Precious metal content is unknown |
AAC | Y |
---|---|
Classification Control | U |
MGMT_CTL | Q2200x- |
Quantity per pack | 1 |
Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Shelf Life | N/A |
SOS | S9e |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | P - 77.5 |
NMFC: | 061300 - Circuit breaker/switch noi |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 658 - Electrical appliances, small |