Are you looking quote for part TS656U? The Roflan Associates Inc-manufactured component (CAGE Code: 86796) is documented under NSN 6625-00-806-4485 as Test Set Electrical. For the fastest quote, please complete our RFQ form with details about TS656U. We guarantee a response within 15 minutes.
ASAP Components provides the verified TS656U, classified under INC 03636, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 00-806-4485, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| SR-1 | SPEC/STD CONTROLLING DATA | |
| ABGL | WIDTH | 14.200 INCHES NOMINAL |
| ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING AND SINGLE ITEM W/CARRYING CASE |
| SR-5 | MANUFACTURERS CODE | 80058 |
| AQXZ | OPERATING TEST CAPABILITY | AC TEST VOLTAGES 0.2.5,5,10,25,50,100,250 AND 500;DC TEST VOLTAGES 0 TO2.5,5,10,25,50,100,250 AND 500 V;DC TEST CURRENT 0 TO 100,250 AND 500 MICRO AMP,0 TO 1,2.5,5,10,25,50,100 AND 500 MA,0 TO 1 AMP |
| AQXY | TEST TYPE FOR WHICH DESIGNED | CALIBRATION OF AC AND DC VOLTMETERS AND OF DC MILLIAMMETERS |
| SR-5 | DESIGN CONTROL REFERENCE | TS656U |
| ANNQ | MATERIAL AND LOCATION | ALUMINUM CARRYING CASE |
| ABRY | LENGTH | 17.700 INCHES NOMINAL |
| SR-5 | THE MANUFACTURERS DATA | |
| SR-1 | MANUFACTURERS CODE | 81349 |
| HGTH | HEIGHT | 11.700 INCHES NOMINAL |
| SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILM11538 |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
| SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | J - 100.0 |
| LTL: | J - 100.0 |
| NMFC: | 061620 - Electric current testers |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 657 - Instruments, electric meter |