Are you looking quote for part I145100? The Rockwell Collins Aerospace-manufactured component (CAGE Code: 13499) is documented under NSN 6680-00-987-3857 as Counter Rotating. For the fastest quote, please complete our RFQ form with details about I145100. We guarantee a response within 15 minutes.
ASAP Components provides the verified I145100, classified under INC 30762, FSG 66 Instruments and Laboratory Equipment, FSC 6680 Liquid And Gas Flow Liquid Level And Mechanical Motion Measuring Instruments, NIIN 00-987-3857, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| ANRD | SHAFT REVOLUTIONS PER COUNT | 0.10 ALL REGISTERS SINGLE TIER |
| ANRE | MAXIMUM COUNT RATE | 10000.0 PER MINUTE ALL REGISTERS SINGLE TIER |
| STYL | STYLE DESIGNATOR | UNENCLOSED SQUARE OR RECTANGULAR |
| BCNX | MOUNTING TYPE FOR WHICH DESIGNED | PANEL ALL REGISTERS SINGLE TIER |
| ABWV | SHAFT DIAMETER | 0.125 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.156 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.593 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.531 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| HUES | COLOR | BLACK ALL REGISTERS SINGLE TIER FIGURE WHITE ALL REGISTERS SINGLE TIER FIGURE BACKGROUND |
| ANQD | REGISTER QUANTITY | 2 |
| CSWT | NUMERAL READOUT | 00 MINIMUM AND 99 MAXIMUM 1ST REGISTER SINGLE TIER 0 MINIMUM AND 9 MAXIMUM 2ND REGISTER SINGLE TIER |
| ANQT | FIGURE HEIGHT | 0.270 INCHES NOMINAL ALL REGISTERS SINGLE TIER |
| AGAV | III END ITEM IDENTIFICATION | 5820-00-230-4428,RECEIVER,RADIO |
| AXEG | ACTUATING DEVICE LOCATION | LEFT SIDE ALL REGISTERS SINGLE TIER |
| ABMK | OVERALL WIDTH | 1.031 INCHES NOMINAL |
| CSWW | SHAFT ROTATION DIRECTION AND MAXIMUM SPEED IN RPM | 10000.0 CLOCKWISE AND 1000.0 COUNTERCLOCKWISE ALL REGISTERS SINGLE TIER |
| CSWS | NUMERAL DISPLAY METHOD | DRUM |
| AXED | REGISTER FUNCTION | ADD ALL REGISTERS SINGLE TIER |
| ABHP | OVERALL LENGTH | 3.155 INCHES NOMINAL |
| ANRL | MOUNTING ARRANGEMENT STYLE | FOUR POSITION SQUARE/RECTANGLE |
| ANQS | FIGURE QUANTITY PER REGISTER | 2 1ST REGISTER SINGLE TIER 1 2ND REGISTER SINGLE TIER |
| ABXF | SHAFT LENGTH | 0.500 INCHES NOMINAL |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9029100000 (NAICS 334514) | Revolution counters, production counters, taximeters, odometers, pedometers and the like |
| SITC : 87321 | Revolution counters, production counters, taximeters, odometers, pedometers and the like |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |
| AAC | V |
|---|---|
| Classification Control | U |
| MGMT_CTL | J2200x- |
| Quantity per pack | 1 |
| Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | S - Office and school supplies and equipment including office machines, furniture and stationary. |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | F - 150.0 |
| NMFC: | 058240 - Recording devices gauges/meters noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 653 - Musical instruments |