Quote for IEL11124943-1-V Perkin-Elmer Corp Part with NSN 5925-01-327-5458

Part Number:  IEL11124943-1-V
Alternate P/N:  IEL111249431V
Manufacturer:  perkin elmer corp
NIIN:  13275458
Item Name :  circuit breaker
CAGE Code:  81511
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  09-25-2026

Are you looking quote for part IEL11124943-1-V? The Perkin-Elmer Corp-manufactured component (CAGE Code: 81511) is documented under NSN 5925-01-327-5458 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about IEL11124943-1-V. We guarantee a response within 15 minutes.

ASAP Components provides the verified IEL11124943-1-V, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-327-5458, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for IEL11124943-1-V

“*” Required Fields Are Compulsory

NSN Information for Part Number IEL11124943-1-V with NSN 5925-01-327-5458, 5925013275458

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-327-5458

Item PartTypeName:

CIRCUIT BREAKER

59250132754580P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
28075310595

Characteristics Data of NSN 5925-01-327-5458, 5925013275458

MRCCriteriaCharacteristic
ADAQBODY LENGTH2.490 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.000 INCHES MAXIMUM
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.180 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD
AFJNFRAGILITY FACTORMODERATELY RUGGED
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.940 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
AJECBOSS HEIGHT0.140 INCHES NOMINAL
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
CTJSUNPACKAGED UNIT WEIGHT11.100 OUNCES NOMINAL
FREQFREQUENCY IN HERTZ50.0 OR 60.0 ALL LOCATIONS
ADATBODY WIDTH2.265 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL
AKPXPOLE QUANTITY3
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.0 AMPERES AC THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CWJKCASE MATERIALPLASTIC
THSDTHREAD SERIES DESIGNATORUNC

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL 9b-----
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships