Are you looking quote for part TLA-3000? The Penril Datacomm-manufactured component (CAGE Code: 57691) is documented under NSN 6625-01-073-8439 as Test Set Telephone. For the fastest quote, please complete our RFQ form with details about TLA-3000. We guarantee a response within 15 minutes.
ASAP Components provides the verified TLA-3000, classified under INC 03681, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 01-073-8439, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| MRC | Decoded Requirement | Clear Text Reply |
| ACYN | Ac Voltage Rating | 207.0 VOLTS MINIMUM AND 253.0 VOLTS MAXIMUM |
| ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
| FAAZ | Phase | SINGLE |
| ABGL | Width | 19.875 INCHES NOMINAL |
| ACYN | Ac Voltage Rating | 103.5 VOLTS MINIMUM AND 126.5 VOLTS MAXIMUM |
| ANPZ | Inclosure Feature | SINGLE ITEM W/CARRYING CASE |
| HGTH | Height | 7.250 INCHES NOMINAL |
| AEJZ | Depth | 14.750 INCHES NOMINAL |
| AQXY | Test Type For Which Designed | AMPLITUDE RESPONSE; RELATIVE ENVELOPE DELAY; HARMONIC DISTORTION; INTERMODULATION DISTORTION; PHASE JITTER; PHASE TRANSIENT HITS; AMPLITUDE GAIN/LOSS HITS; IMPULSE NOISE HITS; SIGNAL-TO-NOISE RATIO; SPECTRUM ANALYSIS; FREQUENCY TRANSLATION; BIT ERROR |
| ALSF | Internal Battery Accommodation | NOT INCLUDED |
| AQXZ | Operating Test Capability | TRANSMIT OUTPUT LEVELS P3 TO M28 DBM; TRANSMIT CARRIER FREQUENCY 300-4000 HZ OR 30-400 HZ; AMPLITUDE RESPONSE RANGE M70-P10 DBM; JITTER RANGE 0-99.9 DEG PEAK-PEAK; ASYNCHRONOUS BIT RATE RANGE 30-4000 BPS |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
| SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |