Are you looking quote for part 1140-G151-P7M1-018808-1A? The Oakland Industries Ltd-manufactured component (CAGE Code: 06402) is documented under NSN 5925-01-170-1758 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 1140-G151-P7M1-018808-1A. We guarantee a response within 15 minutes.
ASAP Components provides the verified 1140-G151-P7M1-018808-1A, classified under INC , FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-170-1758, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-170-1758 Item Description: CIRCUIT BREAKER | 5925 | 011701758 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 1140-G151-P7M1-018808-1A | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| MRC | Decoded Requirement | Clear Text Reply |
| AAQL | Body Style | SINGLE POLE TYPE |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC AND |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC AND |
| ABXD | Bushing Length | 0.650 INCHES NOMINAL |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 100.0 DC SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 100.0 AC AND |
| CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
| ADAT | Body Width | 0.570 INCHES NOMINAL |
| FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
| AKPX | Pole Quantity | 1 |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| CPRQ | Reset Method | MANUAL |
| CRCF | Trip Release Ambient Temp Rating | 70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
| CPRT | Manual Actuator Type And Quantity | 1 PUSH BUTTON |
| CPRW | Actuator Function | TRIP-RESET |
| ADTV | Case Material | PLASTIC |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| CPRX | Actuator Position Designation | AT POLE ONE |
| CQJX | Nominal Thread Size | 0.375 INCHES |
| AJWX | Mounting Surface To Terminal End Distance | 2.260 INCHES NOMINAL |
| ADAQ | Body Length | 1.140 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.780 INCHES NOMINAL |
| THSD | Thread Series Designator | UNS |
| TTQY | Terminal Type And Quantity | 2 PIN |
| PKWT | Unpackaged Unit Weight | 0.062 POUNDS |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES DC SINGLE LOCATION |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT AND |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CMLP | Thread Quantity Per Inch | 27 |
| CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |