Quote for 1140-G151-P7M1-018808-1A Oakland Industries Ltd Part with NSN 5925-01-170-1758

Part Number:  1140-G151-P7M1-018808-1A
Alternate P/N:  1140G151P7M10188081A
Manufacturer:  oakland industries ltd
NIIN:  11701758
Item Name :  circuit breaker
CAGE Code:  06402
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-04-2026

Are you looking quote for part 1140-G151-P7M1-018808-1A? The Oakland Industries Ltd-manufactured component (CAGE Code: 06402) is documented under NSN 5925-01-170-1758 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 1140-G151-P7M1-018808-1A. We guarantee a response within 15 minutes.

ASAP Components provides the verified 1140-G151-P7M1-018808-1A, classified under INC , FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-170-1758, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 1140-G151-P7M1-018808-1A

“*” Required Fields Are Compulsory

NSN Information for Part Number 1140-G151-P7M1-018808-1A with NSN 5925-01-170-1758, 5925011701758

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-170-1758

Item Description:

CIRCUIT BREAKER

59250117017580P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
1140-G151-P7M1-018808-1A523

Characteristics Data of NSN 5925-01-170-1758, 5925011701758

MRCCriteriaCharacteristic
MRCDecoded RequirementClear Text Reply
AAQLBody StyleSINGLE POLE TYPE
CPLMMaximum Continuous Load Current Rating Per Pole1.0 AMPERES AC AND
AFJNFragility FactorMODERATELY RUGGED
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
CPRFOperating Voltage Type And Rating Per Pole In Volts250.0 AC AND
ABXDBushing Length0.650 INCHES NOMINAL
CPRFOperating Voltage Type And Rating Per Pole In Volts28.0 DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps100.0 DC SINGLE LOCATION
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps100.0 AC AND
CPRJTrip Release MethodTHERMAL SINGLE LOCATION
ADATBody Width0.570 INCHES NOMINAL
FREQFrequency In Hertz60.0 SINGLE LOCATION
AXHRMounting Facility Type And Quantity1 THREADED BUSHING
AKPXPole Quantity1
CPRLTrip Release CharacteristicTIME DELAY SINGLE LOCATION
CPRQReset MethodMANUAL
CRCFTrip Release Ambient Temp Rating70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 SINGLE LOCATION
CPRTManual Actuator Type And Quantity1 PUSH BUTTON
CPRWActuator FunctionTRIP-RESET
ADTVCase MaterialPLASTIC
CPSMInternal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
CPRXActuator Position DesignationAT POLE ONE
CQJXNominal Thread Size0.375 INCHES
AJWXMounting Surface To Terminal End Distance2.260 INCHES NOMINAL
ADAQBody Length1.140 INCHES NOMINAL
AEBPCenter To Center Distance Between Terminals Parallel To Length0.780 INCHES NOMINAL
THSDThread Series DesignatorUNS
TTQYTerminal Type And Quantity2 PIN
PKWTUnpackaged Unit Weight0.062 POUNDS
CPLMMaximum Continuous Load Current Rating Per Pole1.0 AMPERES DC SINGLE LOCATION
CPRHCircuit Protection TypeOVERCURRENT SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQWNTrip Delay Time In Seconds Per Rated Continuous Current10.000 MINIMUM AT 200 PCT AND
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
CMLPThread Quantity Per Inch27
CQXFInclosure Protection Type For Which DesignedGENERAL PURPOSE

ASAP Semiconductor’s Certifications And Memberships