Quote for 0-1112T1 Northrop Grumman Systems Corporation Part with NSN 5950-01-064-3841

Part Number:  0-1112T1
Alternate P/N:  01112T1
NIIN:  10643841
Item Name :  transformer power
CAGE Code:  03956
INC Code:  32496
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-10-2026

Are you looking quote for part 0-1112T1? The Northrop Grumman Systems Corporation-manufactured component (CAGE Code: 03956) is documented under NSN 5950-01-064-3841 as Transformer Power. For the fastest quote, please complete our RFQ form with details about 0-1112T1. We guarantee a response within 15 minutes.

ASAP Components provides the verified 0-1112T1, classified under INC 32496, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 01-064-3841, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 0-1112T1

“*” Required Fields Are Compulsory

NSN Information for Part Number 0-1112T1 with NSN 5950-01-064-3841, 5950010643841

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5950-01-064-3841

Item PartTypeName:

TRANSFORMER,POWER

59500106438410P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
0-1112T161CA

Characteristics Data of NSN 5950-01-064-3841, 5950010643841

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.720 INCHES MINIMUM AND 1.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABTBMOUNTING HOLE DIAMETER0.200 INCHES NOMINAL SINGLE GROUP
ACZBFREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAQBODY LENGTH3.060 INCHES MAXIMUM
ADATBODY WIDTH2.360 INCHES MAXIMUM
ADAUBODY HEIGHT1.560 INCHES MAXIMUM
AEHZMAXIMUM OPERATING TEMP115.0 DEG CELSIUS
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODUNTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
CBBLFEATURES PROVIDEDCOLOR CODED LEAD
CRBZWINDING OPERATING CURRENT0.5 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
TTQYTERMINAL TYPE AND QUANTITY6 WIRE LEAD

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Sf9eh-n
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: W - Rating variable
NMFC: 063420 - Transformers, noi, or transformer par
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 595 - Transformer, (machinery and parts),(less than 35 feet)

ASAP Semiconductor’s Certifications And Memberships