Quote for 40082130 Ministry Of Defence Future Part with NSN 5925-01-073-8951

Part Number:  40082130
Manufacturer:  ministry of defence future
NIIN:  10738951
Item Name :  circuit breaker
CAGE Code:  KCUC6
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  02-28-2026

Are you looking quote for part 40082130? The Ministry Of Defence Future-manufactured component (CAGE Code: KCUC6) is documented under NSN 5925-01-073-8951 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 40082130. We guarantee a response within 15 minutes.

ASAP Components provides the verified 40082130, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-073-8951, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 40082130

“*” Required Fields Are Compulsory

NSN Information for Part Number 40082130 with NSN 5925-01-073-8951, 5925010738951

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-073-8951

Item PartTypeName:

CIRCUIT BREAKER

59250107389510P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
396223-351CA

Characteristics Data of NSN 5925-01-073-8951, 5925010738951

MRCCriteriaCharacteristic
AAJETHREAD PITCH DIAMETERS0.3503 TO 0.3537 INCHES
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
ADAQBODY LENGTH1.562 INCHES MAXIMUM
ADATBODY WIDTH1.281 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.906 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY DELICATE
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.828 INCHES MAXIMUM
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.0 AMPERES AC AND 2.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC AND 50.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS300.0 AC AND 500.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.375 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND HERMETICALLY SEALED
CTJSUNPACKAGED UNIT WEIGHT100.0 GRAMS NOMINAL
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS
TESTTEST DATA DOCUMENT81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITY4 WIRE HOOK
ZZZKSPECIFICATION/STANDARD DATA81349-MIL-C-39019/3 GOVERNMENT SPECIFICATION

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

ADPE Represents items with no adp components
CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small