Quote for MS25244-30 Military Standards Corp Part with NSN 5925-01-227-4047

Part Number:  MS25244-30
Alternate P/N:  MS2524430
Manufacturer:  military standards corp
NIIN:  12274047
Item Name :  circuit breaker
CAGE Code:  96906
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-18-2026

Are you looking quote for part MS25244-30? The Military Standards Corp-manufactured component (CAGE Code: 96906) is documented under NSN 5925-01-227-4047 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about MS25244-30. We guarantee a response within 15 minutes.

ASAP Components provides the verified MS25244-30, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-227-4047, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for MS25244-30

“*” Required Fields Are Compulsory

NSN Information for Part Number MS25244-30 with NSN 5925-01-227-4047, 5925012274047

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-227-4047

Item PartTypeName:

CIRCUIT BREAKER

59250122740470P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
10180581396

Characteristics Data of NSN 5925-01-227-4047, 5925012274047

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ABXDBUSHING LENGTH0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
ADAQBODY LENGTH2.189 INCHES MAXIMUM
ADATBODY WIDTH0.750 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.704 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.000 INCHES MAXIMUM
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE30.0 AMPERES AC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS200.0 AC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS3500.0 AC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODTHERMAL SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT200.0 SINGLE LOCATION
CPRPULTIMATE TRIP TIME PER POLE IN SECONDS138.000 NOMINAL SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 SINGLE LOCATION
TESTTEST DATA DOCUMENT81349-MIL-C-5809 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY2 TAB,SOLDER LUG
ZZZKSPECIFICATION/STANDARD DATA96906-MS25244 GOVERNMENT STANDARD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC D
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top