Quote for C0-02LGF 2-22 SJ0160 Military Specifications Part with NSN 6145-01-420-7608

Part Number:  C0-02LGF 2-22 SJ0160
Alternate P/N:  C002LGF222SJ0160
Manufacturer:  military specifications
NIIN:  14207608
Item Name :  cable special purpo
CAGE Code:  81349
INC Code:  00232
Country:  USA
NCB Code:  01
FSG:  61 Electric Wire and Power and Distribution Equipment
Last Updated:  01-17-2026

Are you looking quote for part C0-02LGF 2-22 SJ0160? The Military Specifications-manufactured component (CAGE Code: 81349) is documented under NSN 6145-01-420-7608 as Cable Special Purpo. For the fastest quote, please complete our RFQ form with details about C0-02LGF 2-22 SJ0160. We guarantee a response within 15 minutes.

ASAP Components provides the verified C0-02LGF 2-22 SJ0160, classified under INC 00232, FSG 61 Electric Wire and Power and Distribution Equipment, FSC 6145 Wire and Cable Electrical, NIIN 01-420-7608, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for C0-02LGF 2-22 SJ0160

“*” Required Fields Are Compulsory

NSN Information for Part Number C0-02LGF 2-22 SJ0160 with NSN 6145-01-420-7608, 6145014207608

NSNFSCNIINCLSHazmatDEMILCancelled NSN
6145-01-420-7608

Item PartTypeName:

CABLE,POWER,ELECTRICAL

61450142076080N
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
C0-02LGF(2/22)SJ0160595

Characteristics Data of NSN 6145-01-420-7608, 6145014207608

MRCCriteriaCharacteristic
AAGRCROSS-SECTIONAL SHAPE STYLEROUND"
ABJHTEMP RATING-55.0 DEG CELSIUS AND 75.0 DEG CELSIUS"
ADVLCROSS SECTION OUTSIDE DIAMETER0.160 INCHES NOMINAL"
AMQNIII CONDUCTOR QUANTITY2"
BLNZSTRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS"
CXCWCONDUCTOR FORMSTRANDED ALL CONDUCTORS"
CXDCROUND CONDUCTOR SIZE22 AWG ALL CONDUCTORS"
CXDGSTRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS"
CXDQCONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES"
CXFKVOLTAGE RATING300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS"
HUESCOLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR"
HUESCOLORWHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR"
MATTMATERIALCOPPER 2ND POSITION SHIELD BRAID, METALLIC CABLE"
MATTMATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS"
MATTMATERIALRUBBER BUTADIENE-STYRENE CLASS SBR 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS"
MATTMATERIALRUBBER BUTADIENE-STYRENE CLASS SBR 3RD POSITION JACKET CABLE"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONMIL-I MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONMIL-I-3930 TYPE JS-L 0R TYPE JN-L MIL SPEC SINGLE MATERIAL RESPONSE 3RD POSITION JACKET CABLE"
SFTTSURFACE TREATMENTTIN 2ND POSITION SHIELD BRAID, METALLIC CABLE"
SFTTSURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS"
STDCSURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS"
AAGRCROSS-SECTIONAL SHAPE STYLEROUND"
ABJHTEMP RATING-55.0 DEG CELSIUS AND 75.0 DEG CELSIUS"
ADVLCROSS SECTION OUTSIDE DIAMETER0.160 INCHES NOMINAL"
AMQNIII CONDUCTOR QUANTITY2"
BLNZSTRAND QUANTITY PER CONDUCTOR19 ALL CONDUCTORS"
CXCWCONDUCTOR FORMSTRANDED ALL CONDUCTORS"
CXDCROUND CONDUCTOR SIZE22 AWG ALL CONDUCTORS"
CXDGSTRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS"
CXDQCONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES"
CXFKVOLTAGE RATING300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS"
HUESCOLORBLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR"
HUESCOLORWHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR"
MATTMATERIALCOPPER 2ND POSITION SHIELD BRAID, METALLIC CABLE"
MATTMATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS"
MATTMATERIALRUBBER BUTADIENE-STYRENE CLASS SBR 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS"
MATTMATERIALRUBBER BUTADIENE-STYRENE CLASS SBR 3RD POSITION JACKET CABLE"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONMIL-I MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS"
MDCLMATERIAL DOCUMENT AND CLASSIFICATIONMIL-I-3930 TYPE JS-L 0R TYPE JN-L MIL SPEC SINGLE MATERIAL RESPONSE 3RD POSITION JACKET CABLE"
SFTTSURFACE TREATMENTTIN 2ND POSITION SHIELD BRAID, METALLIC CABLE"
SFTTSURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS"
STDCSURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS"

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8548900100 (NAICS 335999) Electrical parts of machinery or apparatus not specified or included elsewhere in chapter 85
SITC : 77813 Waste and scrap of primary cells, primary batteries and electric accumulators; spent primary cells, etc; electric parts of mach or apps, nes

Identification

ADPE Represents items with no adp components
CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 500
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ft

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: W - Rating variable
NMFC: 030310 - Cable or wire
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 743 - Electrical cable

ASAP Semiconductor’s Certifications And Memberships



bottom to top