Are you looking quote for part 1410-0044? The Agilent Technologies Inc-manufactured component (CAGE Code: 81349) is documented under NSN 5910008507991 as . For the fastest quote, please complete our RFQ form with details about 1410-0044. We guarantee a response within 15 minutes.
ASAP Components provides the verified 1410-0044, classified under INC 00007, FSG 59 Electrical and Electronic Equipment Components, FSC 5910 Capacitors, NIIN , and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5910-00-837-2577 Item PartTypeName: CAPACITOR,FIXED,CERAMIC DIELECTR | 5910 | 008372577 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 0150-0077 | 3 | 8 | E |
| MRC | Criteria | Characteristic |
|---|---|---|
| CQBQ | CAPACITANCE VALUE PER SECTION | 1500.000 PICOFARADS SINGLE SECTION |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
| CRTP | TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
| CWJK | CASE MATERIAL | PLASTIC |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-11015/9D GOVERNMENT SPECIFICATION |
| AAQL | BODY STYLE | W/O MTG FACILITIES,RADIAL TERMINALS |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
| ABPM | BODY DIAMETER | 0.280 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.120 INCHES NOMINAL |
| AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.190 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQFB | VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -66.0 TO 22.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 200000.0 MEGOHMS |
| CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.000 |
| TEST | TEST DATA DOCUMENT | 81349-MIL-C-11015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |