Are you looking quote for part FWC3080JVWA0601? The L 3 Communications Westwood-manufactured component (CAGE Code: 58475) is documented under NSN 5925-01-513-4408 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about FWC3080JVWA0601. We guarantee a response within 15 minutes.
ASAP Components provides the verified FWC3080JVWA0601, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-513-4408, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-513-4408 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015134408 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | A | 0 | |||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| FWC3080JVWA0601 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKPX | Pole Quantity | 3 |
| CSSX | Switch Current Rating And Type In Amps | 6.0 AC |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 80.0 AMPERES AC ALL LOCATIONS |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 690.0 AC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 12000.0 AC ALL LOCATIONS |
| CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 34.930 INCHES NOMINAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 200.0 ALL LOCATIONS |
| CPRQ | Reset Method | MANUAL |
| CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CPRP | Ultimate Trip Time Per Pole In Seconds | 4.000 MINIMUM ALL LOCATIONS AND 20.000 MAXIMUM ALL LOCATIONS |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| AJEC | Boss Height | 4.170 INCHES NOMINAL |
| CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| CPRW | Actuator Function | TRIP-RESET |
| ADTV | Case Material | PLASTIC |
| CPRX | Actuator Position Designation | AT POLE TWO |
| ADAT | Body Width | 70.670 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
| MRC | Decoded Requirement | Clear Text Reply |
| CQJX | Nominal Thread Size | 0.164 INCHES |
| ADAQ | Body Length | 152.400 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 119.080 INCHES NOMINAL |
| ADAU | Body Height | 85.730 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 34.930 INCHES NOMINAL |
| AGAV | End Item Identification | LOAD CTR 28B DDG91 |
| CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| CRTK | Switch Terminal Type | WIRE LEAD |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRZ | Auxiliary Switch Function And Quantity | 1 CONTROL |
| FEAT | Special Features | ADJ THERMAL/MAGNETIC TRIP; W/O TERMINALS |
| THSD | Thread Series Designator | UNC |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 114.300 INCHES NOMINAL |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | No qup |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |