Are you looking quote for part 380A? The Joint Electronics Type Designation System-manufactured component (CAGE Code: 80058) is documented under NSN 6625-00-669-2395 as Generator Signal. For the fastest quote, please complete our RFQ form with details about 380A. We guarantee a response within 15 minutes.
ASAP Components provides the verified 380A, classified under INC 03901, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 00-669-2395, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 18.000 INCHES NOMINAL |
| ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| FEAT | SPECIAL FEATURES | FREQUENCY RATING: 60.0; VOLTAGE RATING: 110.0; MODULATED FREQUENCY RATING: 400 HZ PULSE REPETITION FREQUENCY |
| AFGQ | FREQUENCY RANGE RATING | 20.000 TO 70.000 MEGAHERTZ |
| FAAZ | PHASE | SINGLE |
| SR-5 | MANUFACTURERS CODE | 80138 |
| BHFY | CRYSTAL CONTROLLED FEATURE | PROVIDED |
| BHGB | MAXIMUM SIGNAL OUTPUT | 250 MILLIVOLTS |
| BHGC | SIGNAL OUTPUT CONSTANCY | 20 DB MAX VARIATION THROUGHOUT FREQUENCY RANGE |
| AYYE | MODULATION TYPE | FM |
| ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | FURNISHED WITH STANDARD PULSE TYPE MARKERS OF 25, 35, 55 AND 65 MC |
| ANLC | FREQUENCY BAND QUANTITY | 2 |
| AAXX | MOUNTING TYPE | RACK |
| BHQG | MODULATION DEGREE | 30.0 PERCENT NOMINAL |
| SR-5 | THE MANUFACTURERS DATA | |
| ADTV | CASE MATERIAL | STEEL |
| ADTY | CASE SURFACE TREATMENT | NATURAL |
| BHGD | MODULATOR LOCATION | INTERNAL |
| BDHW | CALIBRATION ACCURACY RATING | PORM 5 PCT ACCURACY |
| ABMK | OVERALL WIDTH | 11.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 10.500 INCHES NOMINAL |
| ACDC | CURRENT TYPE | AC |
| SR-5 | DESIGN CONTROL REFERENCE | 380A |
| AMNE | OUTPUT IMPEDANCE RATING | 70.0 OHMS NOMINAL |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8543200000 (NAICS 334515) | Signal generators |
| SITC : 77878 | Electrical machines and apparatus, having individual functions, n.E.S. (other than particle accelerators) |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | 6rbead- |
| Quantity per pack | 1 |
| Repariability | * special program reparables |
| Shelf Life | N/A |
| SOS | N32 |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | M - 85.0 |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |