Are you looking quote for part JG7039C3? The Honeywell International Inc Div Honeywell Building Solutions-manufactured component (CAGE Code: 94580) is documented under NSN 6680-00-663-8782 as Transmitter Liquid. For the fastest quote, please complete our RFQ form with details about JG7039C3. We guarantee a response within 15 minutes
ASAP Components provides the verified JG7039C3, classified under INC 03372, FSG 66 Instruments and Laboratory Equipment, FSC 6680 Liquid And Gas Flow Liquid Level And Mechanical Motion Measuring Instruments, NIIN 00-663-8782, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
MRC | Criteria | Characteristic |
---|---|---|
AFLW | ACTUATION METHOD | VARYING CAPACITANCE |
ASKY | ELECTRICAL CONNECTION CONTROLLING AGENCY | MINNEAPOLIS HONEYWELL REGULATOR C0 |
ACDC | CURRENT TYPE | AC |
FAAZ | PHASE | SINGLE |
SR-5 | THE MANUFACTURERS DATA | |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL |
AMSE | VOLTAGE RATING | 115.0 VOLTS NOMINAL |
ABHP | OVERALL LENGTH | 17.070 INCHES NOMINAL |
AARA | TERMINAL QUANTITY | 2 |
ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | PART NUMBERS 412270H AND 412270G |
AARB | TERMINAL TYPE | SOCKET AND PIN |
ADAV | OVERALL DIAMETER | 2.000 INCHES NOMINAL |
ADTL | ATTACHMENT FEATURE QUANTITY | 2 |
ASKX | ELECTRICAL CONNECTION QUANTITY | 1 AND 1 |
SR-5 | DESIGN CONTROL REFERENCE | JG7039C3 |
SR-5 | MANUFACTURERS CODE | 94580 |
AXGY | MOUNTING METHOD | CLAMP |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
PMIC | A - Item does not contain precious metal. |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | Sf9sx-n |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | J - 100.0 |
NMFC: | 121570 - Gages air liquid level pressure |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 653 - Musical instruments |