Are you looking quote for part 5166209? The Honeywell International Inc Div Honeywell Building Solutions-manufactured component (CAGE Code: 017N4) is documented under NSN 6625-01-551-2665 as Bolometer Radio Fre. For the fastest quote, please complete our RFQ form with details about 5166209. We guarantee a response within 15 minutes.
ASAP Components provides the verified 5166209, classified under INC 05654, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 01-551-2665, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| BBTQ | Sensing Element Type | THERMISTOR |
| MRC | Decoded Requirement | Clear Text Reply |
| AFGQ | Frequency Range Rating | +45.0 TO 999.9 MEGAHERTZ AND +1.0 TO 18.0 GIGAHERTZ |
| ABHP | Overall Length | 6.660 INCHES NOMINAL |
| ADAV | Overall Diameter | 1.440 INCHES NOMINAL |
| BGWB | Battery Case | NOT PROVIDED |
| AGAV | End Item Identification | F-15 EARTS |
| FEAT | Special Features | POWER RANGE -20.0DBM TO +20.0DBM PEAK; -30.0DBM TO +20.0DBM CW, MAX POWER +23.0DBM, CONNECTION TYPE IS TYPE N MALE RATED AT 50OHMS, CONTROL INPUTS AND OUTPUTS ARE TRIGGER; SAMPLE DELAY; DETECTOR OUT, ACCESSORIES INCLUDE 3 SMB TO BNC TWO METER LONG CABLES AND 3 1.2 METER LONG CABLE HARNESS WRAPS |
| CXCY | Part Name Assigned By Controlling Agency | PEAK POWER SENSOR |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
| SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf8kv-p |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Flz |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | P - 77.5 |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | 3 - Electrostatic sensitive device (esd) |
| WCC: | 738 - Computing equipment, computer components, and circuit cards |