Are you looking quote for part 7013? The Hart Scientific Llc-manufactured component (CAGE Code: 64841) is documented under NSN 6685-01-224-4282 as Calibrator Thermome. For the fastest quote, please complete our RFQ form with details about 7013. We guarantee a response within 15 minutes.
ASAP Components provides the verified 7013, classified under INC 60161, FSG 66 Instruments and Laboratory Equipment, FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, NIIN 01-224-4282, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| BDHW | CALIBRATION ACCURACY RATING | -100 TO -40 DEG C - PORM 5 DEG C; -40 TO +150 DEG C - PORM 1 DEG C; +150 TO +300 DEG C - PORM 5 DEG C |
| ABMK | OVERALL WIDTH | 45.250 INCHES NOMINAL |
| ABFY | OVERALL DEPTH | 26.250 INCHES NOMINAL |
| FAAZ | PHASE | SINGLE |
| ALGC | MOUNTING CONFIGURATION | FREE STANDING CABINET ON CASTORS |
| SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | A-A-59419 |
| BDHS | INSTRUMENT CALIBRATION RANGE | COLD BATH -100 TO +70 DEG C (-148 TO +158 DEG F); HOT BATH +60 TO +300 DEG C (+140 TO +572 DEG F) |
| AWJN | III UNPACKAGED UNIT WEIGHT | 450.000 POUNDS |
| FTLD | III FUNCTIONAL DESCRIPTION | CONSISTS OF 2 INDEPENDENTLY OPERABLE BATH SYSTEMS. EACH BATH HAS ITS OWN TANK WITH A CONSTANT LEVEL TEST WELL & PUMP. EACH HAS ITS OWN TEMPERATURE CONTROLLER, PROBE, & HEATING AND COLLING SYSTEMS. SEPERATE FRONT PANEL POWER CONTROLS, LABELED HOT BATH AND COLD BATH, ALLOW INDEPENDENT POWER UP AND USE. |
| SR-1 | MANUFACTURERS CODE | 58536 |
| RDAL | III REFERENCE DATA AND LITERATURE | COMMERCIAL MANUAL |
| ABKW | OVERALL HEIGHT | 45.000 INCHES NOMINAL |
| ACYN | AC VOLTAGE RATING | 208.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
| FEAT | SPECIAL FEATURES | C/O TWO TEST WELLS, EACH WELL IS 2.6""DIA X 11/3"" DEEP (60 CUBIC INCHES) AND HAVE A 0.25"" DEEP MERCURY TRAP. TRANSFER FLUIDS: COLD BATH - HALOCARBON 0.8; HOT BATH - DOW 710. |
| SR-1 | SPEC/STD CONTROLLING DATA | |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| BDHR | CALIBRATION TYPE | DEG CELSIUS AND DEG FAHRENHEIT |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | Afyrn-e |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Flz |
| Unit of Measure | Ea |
| ACC: | V - Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | J - 100.0 |
| LTL: | J - 100.0 |
| NMFC: | 121570 - Gages air liquid level pressure |
| SHC: | Z - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 653 - Musical instruments |