Quote for AKR-10S-30 General Electric Company Part with NSN 5925-01-397-0559

Part Number:  AKR-10S-30
Alternate P/N:  AKR10S30
Manufacturer:  general electric company
NIIN:  13970559
Item Name :  circuit breaker
CAGE Code:  60969
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-04-2026

Are you looking quote for part AKR-10S-30? The General Electric Company-manufactured component (CAGE Code: 60969) is documented under NSN 5925-01-397-0559 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about AKR-10S-30. We guarantee a response within 15 minutes.

ASAP Components provides the verified AKR-10S-30, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-397-0559, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for AKR-10S-30

“*” Required Fields Are Compulsory

NSN Information for Part Number AKR-10S-30 with NSN 5925-01-397-0559, 5925013970559

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-397-0559

Item PartTypeName:

CIRCUIT BREAKER

59250139705590P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
AKR-10S-30523

Characteristics Data of NSN 5925-01-397-0559, 5925013970559

MRCCriteriaCharacteristic
MRCDecoded RequirementClear Text Reply
CQQCTrip Release Duty CycleINTERMITTENT ALL LOCATIONS
CPRFOperating Voltage Type And Rating Per Pole In Volts600.0 AC ALL LOCATIONS
FREQFrequency In Hertz50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
FEATSpecial FeaturesITEM IS AN AIR CIRCUIT BREAKER DRAWOUT TYPE
CPRGMaximum Interrupting Capacity Current Type And Rating Per Pole In Amps800.0 AC ALL LOCATIONS
CPRHCircuit Protection TypeUNDERVOLTAGE SECOND LOCATION
CPRKAuxiliary Trip Coil Voltage Type And Rating In Volts120.0 AC NOMINAL ALL LOCATIONS
CPRHCircuit Protection TypeOVERCURRENT FIRST LOCATION
CPRLTrip Release CharacteristicINSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS
CPRQReset MethodELECTRIC
CPRNUltimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 ALL LOCATIONS
CPSMInternal Trip Release ConfigurationSERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE ALL LOCATIONS
AGAVEnd Item IdentificationSWITCHBOARD ONBOARD 210 FT MMA CLASS COAST GUARD VESSELS
CPLMMaximum Continuous Load Current Rating Per Pole800.0 AMPERES AC ALL LOCATIONS
ADTVCase MaterialMETAL
CPRJTrip Release MethodMAGNETIC ALL LOCATIONS
CPRRMain Contact Tripping Mechanism TypeTRIP FREE
AKPXPole Quantity3

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC C
Classification Control U
MGMT_CTL S-09---
Quantity per pack 1
Repariability Reparable item. Repair, condemnation, and disposal not authorized below depot (inventory control point (icp)) level.
Shelf Life N/A
SOS Znc
Unit of Measure Ea

ASAP Semiconductor’s Certifications And Memberships



bottom to top