Are you looking quote for part AKR-7B-30? The General Electric Company-manufactured component (CAGE Code: 60969) is documented under NSN 5925-01-120-0886 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about AKR-7B-30. We guarantee a response within 15 minutes.
ASAP Components provides the verified AKR-7B-30, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-120-0886, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-120-0886 Item PartTypeName: CIRCUIT BREAKER | 5925 | 011200886 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| AKR-7B-30 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| ABHP | OVERALL LENGTH | 27.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 22.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 20.380 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.690 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | S/S SWITCHBOARD ABOARD 140 FT WTGB CLASS COAST GUARD VESSELS |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 400.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 440.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 42000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | SOLID STATE ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | ELECTRIC |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CQTL | RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 22.000 MAXIMUM AT 125 PCT ALL LOCATIONS |
| FEAT | SPECIAL FEATURES | CIRCUIT BREAKER IS A DRAWOUT TYPE EQUIPPED WITH LONG AND SHORT TIME INSTANTANEOUS TRIP; 120VAC SHUNT TRIP W/REMOTE RELEASE; 6 STAGE AUX SWITCHES W/6NO-6NC CONTACTS |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 BUS BAR |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | A-09--- |
| Quantity per pack | 1 |
| Repariability | Reparable item. Repair, condemnation, and disposal not authorized below depot (inventory control point (icp)) level. |
| Shelf Life | N/A |
| SOS | Znc |
| Unit of Measure | Ea |