Quote for AK2-50-1600A3P General Electric Company Part with NSN 5925-00-950-6701

Part Number:  AK2-50-1600A3P
Alternate P/N:  AK2501600A3P
Manufacturer:  general electric company
NIIN:  9506701
Item Name :  circuit breaker
CAGE Code:  60969
INC Code:  00136
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-21-2026

Are you looking quote for part AK2-50-1600A3P? The General Electric Company-manufactured component (CAGE Code: 60969) is documented under NSN 5925-00-950-6701 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about AK2-50-1600A3P. We guarantee a response within 15 minutes.

ASAP Components provides the verified AK2-50-1600A3P, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 00-950-6701, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for AK2-50-1600A3P

“*” Required Fields Are Compulsory

NSN Information for Part Number AK2-50-1600A3P with NSN 5925-00-950-6701, 5925009506701

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-950-6701

Item PartTypeName:

CIRCUIT BREAKER

5925009506701P
CIICHCCESDPMICCriticalityENAC
U
Part NumberISCRNVCRNCCHCCMSDSSADC
AK2-50-1600A3P223

Characteristics Data of NSN 5925-00-950-6701, 5925009506701

MRCCriteriaCharacteristic
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.562 INCHES NOMINAL
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
CBBLFEATURES PROVIDEDADJUSTABLE TRIP RELEASE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE200.0 AMPERES AC AND 200.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS600.0 AC AND 250.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS42000.0 AC AND 42000.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT5.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION PROOF
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY6 SCREW

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown