Quote for 9LA15B22 General Electric Company Part with NSN 5920-00-840-8409

Part Number:  9LA15B22
Manufacturer:  general electric company
NIIN:  8408409
Item Name :  arrester electrical
CAGE Code:  95018
INC Code:  00381
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-10-2026

Are you looking quote for part 9LA15B22? The General Electric Company-manufactured component (CAGE Code: 95018) is documented under NSN 5920-00-840-8409 as Arrester Electrical. For the fastest quote, please complete our RFQ form with details about 9LA15B22. We guarantee a response within 15 minutes.

ASAP Components provides the verified 9LA15B22, classified under INC 00381, FSG 59 Electrical and Electronic Equipment Components, FSC 5920 Fuses Arresters Absorbers and Protector, NIIN 00-840-8409, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 9LA15B22

“*” Required Fields Are Compulsory

NSN Information for Part Number 9LA15B22 with NSN 5920-00-840-8409, 5920008408409

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5920-00-840-8409

Item PartTypeName:

ARRESTER,ELECTRICAL SURGE

59200084084090P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
9L15BCB007295

Characteristics Data of NSN 5920-00-840-8409, 5920008408409

MRCCriteriaCharacteristic
AARATERMINAL QUANTITY3
ABHPOVERALL LENGTH5.750 INCHES NOMINAL
ALBYUSAGE DESIGNOUTDOOR
ALGCMOUNTING CONFIGURATIONONE 7/16 IN. DIA HOLE AND TWO 3/16 IN. DIA HOLES,SMALLER HOLES EQUALLY SPACED DIAGONALLY ABOUT LARGER HOLE ON 5/16 IN. BY 5/8 IN. MTG CENTERS
AQAQBREAKDOWN VOLTAGE2.800 KILOVOLTS NOMINAL
AQARLINE TO GROUND VOLTAGE650.000 VOLTS NOMINAL
AXGYMOUNTING METHODHOLE
CSCFTERMINAL TYPEWIRE LEAD
ABFYOVERALL DEPTH3.219 INCHES NOMINAL
ABMKOVERALL WIDTH2.938 INCHES NOMINAL
AQAPARRESTER TYPEDIELECTRIC

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8535400000 (NAICS 335931) Lightning arrestors, voltage limiters and surge suppressors, for voltage exceeding 1000 v
SITC : 77245 Lightning arresters, voltage limiters and surge suppressors for a voltage exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

NSN Management Codes

AAC Y
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 062380 - Lightning arresters/parts noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top