Quote for 18267 Freed Transformer Company Part with NSN 5950-00-189-4954

Part Number:  18267
Manufacturer:  freed transformer company
NIIN:  1894954
Item Name :  transformer power
CAGE Code:  73386
INC Code:  32496
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-16-2026

Are you looking quote for part 18267? The Freed Transformer Company-manufactured component (CAGE Code: 73386) is documented under NSN 5950-00-189-4954 as Transformer Power. For the fastest quote, please complete our RFQ form with details about 18267. We guarantee a response within 15 minutes.

ASAP Components provides the verified 18267, classified under INC 32496, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 00-189-4954, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 18267

“*” Required Fields Are Compulsory

NSN Information for Part Number 18267 with NSN 5950-00-189-4954, 5950001894954

NSNFSCNIINCLSHazmat DEMILCancelled NSN
5950-00-189-4954

Item Description:

TRANSFORMER,POWER

5950001894954P
CIICHCCESD PMICCriticalityENAC
Part NumberISCRNVCRNCCHCCMSDSSADC
18267623

Characteristics Data of NSN 5950-00-189-4954, 5950001894954

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ACZBFREQUENCY RATING60.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.6 KILOHERTZ MAXIMUM SINGLE COMPONENT"
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT"
ACZXWINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT"
ADAQBODY LENGTH2.875 INCHES NOMINAL"
ADATBODY WIDTH2.875 INCHES NOMINAL"
ADAUBODY HEIGHT3.312 INCHES NOMINAL"
AKNAINCLOSURE TYPEHERMETICALLY SEALED"
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP"
AXGYMOUNTING METHODTHREADED STUD SINGLE GROUP"
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT"
CRBZWINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY"
CRBZWINDING OPERATING CURRENT45.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY"
CWJSWINDING OPERATING VOLTAGE110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY"
CWJSWINDING OPERATING VOLTAGE370.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY"
CWJSWINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY"
TTQYTERMINAL TYPE AND QUANTITY7 STANDOFF, SOLDER LUG"
AARGRELIABILITY INDICATORNOT ESTABLISHED"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ACZBFREQUENCY RATING60.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.6 KILOHERTZ MAXIMUM SINGLE COMPONENT"
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT"
ACZXWINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT"
ADAQBODY LENGTH2.875 INCHES NOMINAL"
ADATBODY WIDTH2.875 INCHES NOMINAL"
ADAUBODY HEIGHT3.312 INCHES NOMINAL"
AKNAINCLOSURE TYPEHERMETICALLY SEALED"
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP"
AXGYMOUNTING METHODTHREADED STUD SINGLE GROUP"
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT"
CRBZWINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY"
CRBZWINDING OPERATING CURRENT45.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY"
CWJSWINDING OPERATING VOLTAGE110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY"
CWJSWINDING OPERATING VOLTAGE370.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY"
CWJSWINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY"
TTQYTERMINAL TYPE AND QUANTITY7 STANDOFF, SOLDER LUG"

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LCL: P - 77.5
LTL: W - Rating variable
NMFC: 063420 - Transformers, noi, or transformer par
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 595 - Transformer, (machinery and parts),(less than 35 feet)