Are you looking quote for part THERMACAM-E2? The Flir Systems Inc-manufactured component (CAGE Code: 56889) is documented under NSN 6685-01-518-3598 as Pyrometer Indicatin. For the fastest quote, please complete our RFQ form with details about THERMACAM-E2. We guarantee a response within 15 minutes
ASAP Components provides the verified THERMACAM-E2, classified under INC 07343, FSG 66 Instruments and Laboratory Equipment, FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, NIIN 01-518-3598, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
MRC | Criteria | Characteristic |
---|---|---|
MATT | Material | PLASTIC OVERALL OR RUBBER SYNTHETIC OVERALL |
ABMK | Overall Width | 3.200 INCHES NOMINAL |
ABFY | Overall Depth | 4.100 INCHES NOMINAL |
APTF | Meter Body Diameter | 1.000 INCHES NOMINAL |
ADAV | Overall Diameter | 19.000 INCHES NOMINAL |
AWAG | Scale Smallest Increment | 1.0 DEG CELSIUS |
ATEQ | Scale Type | ENCLOSED GLASS |
BFHZ | Measurement Type | DIGITAL |
STYL | Style Designator | PORTABLE, HANDHELD |
CXCY | Part Name Assigned By Controlling Agency | CAMERA,THERMOGRAPHY OR THERMACAM |
CSYG | Scale Measurement Range | -20.000/+250.000 DEG CELSIUS |
CSYJ | Pointer/Pen Type And Quantity | 1 INDICATING MULTIPLE |
BGLB | Scale Length | 10.700 INCHES NOMINAL |
FEAT | Special Features | HANDHELD INFARED CAMERA,12 DEG C THERMAL SENSITIVITY,SPECTRAL RANGE 7.5 TO 13 UM,FIELD OF VIEW 25 X 19 INCHS,2.5 16K COLOR LCD DISPLAY,MEASURES MAX,MIN,AVERAGE AREAS,STORAGE,100 CALIBRATED J PEG IMAGES, L1-10N BATTERY TYPE LAST 1.5 HRS,BATTERY CHARGES IN CAMERA,AC 90-260 VAC, OPTIONAL 2 BAY CHARGER11-16 VDC,AUTOMATIC SHUTDOWN AND SLEEP,OPERATING TEMP P5/N113 DEG F,STANDARD1/4-20 TRIPOD MOUNTING,USB INTERFACE STANDARD,OPTIONAL RS232 CABLE,INTERCHANGEABLE LENSES 3X OR 0.5 |
ABKW | Overall Height | 4.100 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
ASNN | Depth To Panel | 1.000 INCHES NOMINAL |
ABHP | Overall Length | 10.400 INCHES NOMINAL |
End Use : 21160 | Measuring, testing, control instruments |
---|---|
Schedule B : 9025194000 (NAICS 334513) | Pyrometers not combined with other instruments |
SITC : 87455 | Hydrometers and similar floating instruments, thermometers, pyrometers, barometers, hygrometers, psychrometers or any combination of these instruments |
ADPE | Represents items with no adp components |
---|---|
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | --sfr-n |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | F01 |
Unit of Measure | Ea |