Are you looking quote for part LE414-0010-3157? The Federal Mogul Corporation-manufactured component (CAGE Code: 1W025) is documented under NSN 5935-01-347-1575 as Connector Receptacl. For the fastest quote, please complete our RFQ form with details about LE414-0010-3157. We guarantee a response within 15 minutes.
ASAP Components provides the verified LE414-0010-3157, classified under INC 15093, FSG 59 Electrical and Electronic Equipment Components, FSC 5935 Connectors Electrical, NIIN 01-347-1575, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5935-01-347-1575 Item PartTypeName: CONNECTOR,RECEPTACLE,ELECTRICAL | 5935 | 013471575 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | G | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 05A132T25B19S | 2 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AFQX | CONTACT POSITION ARRANGEMENT STYLE | 25-19 SINGLE MATING END |
| AFQZ | CONTACT REMOVABILITY | REMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| CMLP | THREAD QUANTITY PER INCH | 18 |
| AAJF | THREAD DIRECTION | RIGHT-HAND |
| AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 1.691 INCHES MINIMUM AND 1.701 INCHES MAXIMUM |
| AFRT | SHELL TYPE | SOLID |
| AWTN | OPERATING TEMP RATING | -65.0 DEG CELSIUS MINIMUM AND 175.0 DEG CELSIUS MAXIMUM |
| CBBL | FEATURES PROVIDED | SCOOPPROOF DESIGN |
| CQYH | CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END SINGLE CONTACT GROUPING |
| CQZG | INSERT MATERIAL | PLASTIC EPOXY SINGLE MATING END |
| AAJD | THREAD CLASS | 2A |
| AAQL | BODY STYLE | STRAIGHT SHAPE,EXTERNAL COUPLING |
| ABHP | OVERALL LENGTH | 2.219 INCHES MAXIMUM |
| ADAV | OVERALL DIAMETER | 2.348 INCHES MAXIMUM |
| AFQQ | MOUNTING FACILITY THICKNESS | 0.125 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |
| AFQR | THREADED DEVICE TYPE | BACK SHELL AND MOUNTING BUSHING |
| AFQW | MATING END QUANTITY | 1 |
| AFRN | POLARIZATION METHOD | KEYWAY OR MULTIPLE KEYWAY |
| AFRP | INSERT POSITION IN DEG | 0.0 AND 95.0 AND 132.0 AND 232.0 AND 260.0 |
| CQJX | NOMINAL THREAD SIZE | 1.438 INCHES AND 1.750 INCHES |
| CQTM | TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| CQTZ | CONTACT MATERIAL | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
| CRBJ | CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-G-45204 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
| CSCF | TERMINAL TYPE | CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
| CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
| CSWM | SHELL SURFACE TREATMENT | CADMIUM AND CHROMATE AND NICKEL |
| CXCJ | BUSHING ACCOMMODATION HOLE SHAPE | ROUND W/FLAT |
| CXCL | INCLUDED CONTACT TYPE | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
| PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
| PRMT | PRECIOUS MATERIAL | GOLD |
| ADZC | ENVIRONMENTAL PROTECTION | MOISTURE PROOF AND SALT WATER RESISTANT AND VIBRATION PROOF AND CORROSION RESISTANT AND DUST RESISTANT AND FUEL RESISTANT AND FUNGUS RESISTANT AND HUMIDITY RESISTANT AND OIL RESISTANT AND SHOCK RESISTANT AND THERMAL SHOCK RESISTANT AND VIBR |
| AFRV | CONNECTOR LOCKING METHOD | BAYONET PIN |
| AKMG | NOMINAL THREAD LENGTH | 0.219 INCHES AND 0.252 INCHES |
| CTBC | SHELL SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416,TYPE 2,CLASS II FED SPEC 1ST TREATMENT RESPONSE AND QQ-P-416,TYPE 2,CLASS II FED SPEC 2ND TREATMENT RESPONSE |
| CXCG | INCLUDED CONTACT QUANTITY | 19 SINGLE MATING END SINGLE CONTACT GROUPING |
| FEAT | SPECIAL FEATURES | FURNISHED ITEMS SPARE CONTACT |
| PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.019 GOLD GRAINS,TROY |
| THSD | THREAD SERIES DESIGNATOR | UNEF AND UNS |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8538907080 (NAICS 335314) | Parts suitable for use solely or principally with the apparatus for heading 8535, 8536, 8537, nesoi |
| SITC : 77282 | Parts of electrical apparatus for switching or protecting electrical circuits for making connections to or in electrical circuits, n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | G - Item contains gold. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9eh-n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 061680 - Elec wiring plugs etc |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |