Quote for 402092-001 Engineered Electric Company Part with NSN 5930-01-223-6414

Part Number:  402092-001
Alternate P/N:  402092001
Manufacturer:  engineered electric company
NIIN:  12236414
Item Name :  switch rotary
CAGE Code:  93742
FSC:  5930 Switches
INC Code:  02134
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-13-2026

Are you looking quote for part 402092-001? The Engineered Electric Company-manufactured component (CAGE Code: 93742) is documented under NSN 5930-01-223-6414 as Switch Rotary. For the fastest quote, please complete our RFQ form with details about 402092-001. We guarantee a response within 15 minutes.

ASAP Components provides the verified 402092-001, classified under INC 02134, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-223-6414, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 402092-001

“*” Required Fields Are Compulsory

NSN Information for Part Number 402092-001 with NSN 5930-01-223-6414, 5930012236414

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5930-01-223-6414

Item PartTypeName:

SWITCH,ROTARY

59300122364140P
CIICHCCESDPMICCriticalityENAC
U S
Part NumberISCRNVCRNCCHCCMSDSSADC
2412H525

Characteristics Data of NSN 5930-01-223-6414, 5930012236414

MRCCriteriaCharacteristic
AAJDTHREAD CLASS2B SINGLE MOUNTING FACILITY
ABHPOVERALL LENGTH7.860 INCHES NOMINAL
ABKWOVERALL HEIGHT2.910 INCHES NOMINAL
ABMKOVERALL WIDTH2.810 INCHES NOMINAL
AFBHINDIVIDUAL SECTION QUANTITY6
AFDSLONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFDTSHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFDVLONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS2.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFGAOPERATING TEMP RANGE-25.0 TO 125.0 DEG FAHRENHEIT
AGAVEND ITEM IDENTIFICATION6115-00-450-5881 GENERATOR SET D
AJZESWITCH CONTACT BASIC DESIGNNONPILE-UP NONSYMMETRICAL
AXGYMOUNTING METHODTHREADED HOLE SINGLE MOUNTING FACILITY
CBBLFEATURES PROVIDEDACTUATOR KNOB AND LEGEND PLATE
CMLPTHREAD QUANTITY PER INCH24 SINGLE MOUNTING FACILITY
CQJXNOMINAL THREAD SIZE0.190 INCHES SINGLE MOUNTING FACILITY
CQMKCONTACT VOLTAGE RATING IN VOLTS125.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL
CQMKCONTACT VOLTAGE RATING IN VOLTS355.0 DC AT SEA LEVEL
CQMKCONTACT VOLTAGE RATING IN VOLTS500.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL
CQYJMOUNTING FACILITY PATTERNISOSCELES TRIANGLE SINGLE MOUNTING FACILITY
CRJHSWITCH ACTUATOR INDEXING POSITION QUANTITY5 SINGLE ACTUATOR
CSCFTERMINAL TYPETAB W/SCREW
CSHWCONTACT SWITCHING ACTIONMAKES BEFORE BREAKS EACH SECTION PERIPHERY
CSLCSWITCH ACTUATOR POSITIONING INCREMENT45.0 DEGREES SINGLE ACTUATOR
CTDNSWITCH ACTUATOR STOP DEVICE TYPEFIXED STOP SINGLE ACTUATOR
CTHFCONTACT LOAD CURRENT RATING20.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL
CTHFCONTACT LOAD CURRENT RATING400.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL
CTHFCONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL
PMLCPRECIOUS MATERIAL AND LOCATIONCONTACT AND TERMINAL SURFACES SILVER
PRMTPRECIOUS MATERIALSILVER
STYLSTYLE DESIGNATORTAP,CIRCUIT SELECTOR
THSDTHREAD SERIES DESIGNATORUNC SINGLE MOUNTING FACILITY

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536509025 (NAICS 335931) Switches, rotary, rated at over 5 a, for a voltage not exceeding 1, 000 volts
SITC : 77255 Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC S - Item contains silver.

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. refer to appropriate manuals or directives for specific instructions.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components

ASAP Semiconductor’s Certifications And Memberships



bottom to top