Are you looking quote for part FT1001? The Electrocube Inc-manufactured component (CAGE Code: 14752) is documented under NSN 5950-01-374-7753 as Transformer Power A. For the fastest quote, please complete our RFQ form with details about FT1001. We guarantee a response within 15 minutes.
ASAP Components provides the verified FT1001, classified under INC 36166, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 01-374-7753, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-374-7753 Item PartTypeName: TRANSFORMER,POWER AUTOTRANSFORME | 5950 | 013747753 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 61551-05011-101 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| MRC | Decoded Requirement | Clear Text Reply |
| CWJS | Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
| CWJS | Winding Operating Voltage | 29.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
| TTQY | Terminal Type And Quantity | 3 THREADED STUD |
| AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
| CRBZ | Winding Operating Current | 17.3 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
| ACZB | Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| BPLC | Winding Function And Quantity | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
| ABTB | Mounting Hole Diameter | 0.218 INCHES MINIMUM SINGLE GROUP AND 0.228 INCHES MAXIMUM SINGLE GROUP |
| ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRMJ | Winding Power Rating | 2.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| ADAT | Body Width | 3.500 INCHES MAXIMUM |
| AKNA | Inclosure Type | FULLY INCLOSED |
| ADAQ | Body Length | 3.750 INCHES MAXIMUM |
| ADAU | Body Height | 4.000 INCHES MAXIMUM |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| End Use : 20000 | Generators, accessories |
|---|---|
| Schedule B : 8504500000 (NAICS 334416) | Inductors, nesoi |
| SITC : 77125 | Electrical inductors, n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9---n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 063420 - Transformers, noi, or transformer par |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |