Quote for TK733-4120 ITEM 1-7 Electric Boat Corporation Part with NSN 5925-01-299-3672

Part Number:  TK733-4120 ITEM 1-7
Alternate P/N:  TK7334120ITEM17
Manufacturer:  electric boat corporation
NIIN:  12993672
Item Name :  circuit breaker
CAGE Code:  96169
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-17-2026

Are you looking quote for part TK733-4120 ITEM 1-7? The Electric Boat Corporation-manufactured component (CAGE Code: 96169) is documented under NSN 5925-01-299-3672 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about TK733-4120 ITEM 1-7. We guarantee a response within 15 minutes.

ASAP Components provides the verified TK733-4120 ITEM 1-7, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-299-3672, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for TK733-4120 ITEM 1-7

“*” Required Fields Are Compulsory

NSN Information for Part Number TK733-4120 ITEM 1-7 with NSN 5925-01-299-3672, 5925012993672

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-299-3672

Item PartTypeName:

CIRCUIT BREAKER

59250129936720P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
209-2-162F8420H51CA

Characteristics Data of NSN 5925-01-299-3672, 5925012993672

MRCCriteriaCharacteristic
AFJNFRAGILITY FACTORMODERATELY RUGGED
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 18.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ50.0 OR 60.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
ADATBODY WIDTH2.072 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AKPXPOLE QUANTITY2
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH5.785 INCHES MINIMUM AND 5.815 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.735 INCHES MINIMUM AND 2.765 INCHES MAXIMUM
AJECBOSS HEIGHT0.205 INCHES MINIMUM AND 0.235 INCHES MAXIMUM
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE20.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS480.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL 9b-----
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top