Are you looking quote for part 124204? The Edo Corporation-manufactured component (CAGE Code: 9Y580) is documented under NSN 5925-01-523-1915 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 124204. We guarantee a response within 15 minutes.
ASAP Components provides the verified 124204, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-523-1915, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-523-1915 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015231915 | P | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 124204 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| ADAU | BODY HEIGHT | 38.0 MILLIMETERS NOMINAL |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 12.0 MILLIMETERS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF AND SHOCKPROOF AND VIBRATIONPROOF |
| ABXD | BUSHING LENGTH | 6.5 MILLIMETERS NOMINAL |
| AGAV | III END ITEM IDENTIFICATION | ALOFTS SONAR SYSTEM, MODEL 980 (V1) |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC AND 28.0 DC ALL LOCATIONS |
| AKPX | POLE QUANTITY | 3 |
| ADTV | CASE MATERIAL | PLASTIC |
| FEAT | SPECIAL FEATURES | BLACK PUSH BUTTON |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 7.5 AMPERES AC AND 7.5 AMPERES DC ALL LOCATIONS |
| ADAT | BODY WIDTH | 45.0 MILLIMETERS NOMINAL |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2500.0 AC AND 6000.0 DC ALL LOCATIONS |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQQR | THREAD PITCH IN MILLIMETERS | 1.25 |
| ADAQ | BODY LENGTH | 19.5 MILLIMETERS NOMINAL |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 12.8 MILLIMETERS NOMINAL |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | ISO M |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 15.0 MILLIMETERS NOMINAL |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |