Are you looking quote for part KB3090? The Eaton Corporation-manufactured component (CAGE Code: 89946) is documented under NSN 5925-01-278-7968 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about KB3090. We guarantee a response within 15 minutes.
ASAP Components provides the verified KB3090, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-278-7968, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-278-7968 Item Description: CIRCUIT BREAKER | 5925 | 012787968 | P | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| KB3090 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 7.940 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 90.0 AMPERES AC ALL LOCATIONS |
| AKPX | Pole Quantity | 3 |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 900.0 AC ALL LOCATIONS |
| CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.375 INCHES NOMINAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| AJEC | Boss Height | 0.187 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |
| CPRW | Actuator Function | TRIP-RESET |
| AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
| CPRX | Actuator Position Designation | AT POLE TWO |
| ADTV | Case Material | PLASTIC |
| ADAT | Body Width | 4.125 INCHES NOMINAL |
| CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +450.0/+900.0 AC ALL LOCATIONS |
| TTQY | Terminal Type And Quantity | 6 COMPRESSION |
| CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
| MRC | Decoded Requirement | Clear Text Reply |
| ADAQ | Body Length | 10.000 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 8.375 INCHES NOMINAL |
| ADAU | Body Height | 4.062 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
| CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| AEBV | Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |