Quote for GJ4-Z4-1 Eaton Corporation Part with NSN 5925-01-222-4379

Part Number:  GJ4-Z4-1
Alternate P/N:  GJ4Z41
Manufacturer:  eaton corporation
NIIN:  12224379
Item Name :  circuit breaker
CAGE Code:  74193
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  03-15-2026

Are you looking quote for part GJ4-Z4-1? The Eaton Corporation-manufactured component (CAGE Code: 74193) is documented under NSN 5925-01-222-4379 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about GJ4-Z4-1. We guarantee a response within 15 minutes.

ASAP Components provides the verified GJ4-Z4-1, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-222-4379, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for GJ4-Z4-1

“*” Required Fields Are Compulsory

NSN Information for Part Number GJ4-Z4-1 with NSN 5925-01-222-4379, 5925012224379

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-222-4379

Item PartTypeName:

CIRCUIT BREAKER

59250122243790P
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
68394009-001523

Characteristics Data of NSN 5925-01-222-4379, 5925012224379

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH7.120 INCHES NOMINAL
ADATBODY WIDTH6.000 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH5.940 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.500 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.828 INCHES NOMINAL
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE,DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.220 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE4.300 INCHES NOMINAL
AKPXPOLE QUANTITY4
APNQARC QUENCHING METHODDEION
AXHRMOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE130.0 AMPERES DC FOURTH LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE45.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE45.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE45.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS130.0 DC FOURTH LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 DC FOURTH LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS18000.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS18000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS18000.0 AC THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY4 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,THREE,AND FOUR LINKED
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY2 CONTROL
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP FOURTH LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATION
CQJXNOMINAL THREAD SIZE0.190 INCHES
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT EACH POLE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.250 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.250 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.250 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.900 MINIMUM AT 200 PCT AND 1.300 MAXIMUM AT 200 PCT FOURTH LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
CRTKSWITCH TERMINAL TYPETAB,SOLDER LUG
CSSXSWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 10.0 DC
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 30.0 DC
CWJKCASE MATERIALPLASTIC
FEATSPECIAL FEATURESRELAY COIL RATED AT 24.0 VDC,16.0 OHMS
FREQFREQUENCY IN HERTZ400.0 FIRST LOCATION
FREQFREQUENCY IN HERTZ400.0 SECOND LOCATION
FREQFREQUENCY IN HERTZ400.0 THIRD LOCATION
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY8 THREADED STUD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

ADPE Represents items with no adp components
CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Sf9eh-e
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small