Quote for AM2-Z229-5 Eaton Corporation Part with NSN 5925-01-159-6611

Part Number:  AM2-Z229-5
Alternate P/N:  AM2Z2295
Manufacturer:  eaton corporation
NIIN:  11596611
Item Name :  circuit breaker
CAGE Code:  74193
INC Code:  00136
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-11-2026

Are you looking quote for part AM2-Z229-5? The Eaton Corporation-manufactured component (CAGE Code: 74193) is documented under NSN 5925-01-159-6611 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about AM2-Z229-5. We guarantee a response within 15 minutes.

ASAP Components provides the verified AM2-Z229-5, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-159-6611, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for AM2-Z229-5

“*” Required Fields Are Compulsory

NSN Information for Part Number AM2-Z229-5 with NSN 5925-01-159-6611, 5925011596611

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-159-6611

Item PartTypeName:

CIRCUIT BREAKER

59250115966110P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
979212-5523

Characteristics Data of NSN 5925-01-159-6611, 5925011596611

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
ADATBODY WIDTH1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES DC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS28.0 DC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 DC FIRST LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.600 MINIMUM AT 300 PCT AND 5.000 MAXIMUM AT 300 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CTJSUNPACKAGED UNIT WEIGHT6.500 OUNCES NOMINAL
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 SECOND LOCATION
TESTTEST DATA DOCUMENT49956-979212 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships