Quote for HE2-A3B3L10-240-1-60HZ-R10-50DC2 Eaton Corporation Part with NSN 5925-00-906-1963

Part Number:  HE2-A3B3L10-240-1-60HZ-R10-50DC2
Alternate P/N:  HE2A3B3L10240160HZR1050DC2
Manufacturer:  eaton corporation
NIIN:  9061963
Item Name :  circuit breaker
CAGE Code:  74193
INC Code:  00136
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  01-14-2026

Are you looking quote for part HE2-A3B3L10-240-1-60HZ-R10-50DC2? The Eaton Corporation-manufactured component (CAGE Code: 74193) is documented under NSN 5925-00-906-1963 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about HE2-A3B3L10-240-1-60HZ-R10-50DC2. We guarantee a response within 15 minutes.

ASAP Components provides the verified HE2-A3B3L10-240-1-60HZ-R10-50DC2, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 00-906-1963, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for HE2-A3B3L10-240-1-60HZ-R10-50DC2

“*” Required Fields Are Compulsory

NSN Information for Part Number HE2-A3B3L10-240-1-60HZ-R10-50DC2 with NSN 5925-00-906-1963, 5925009061963

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-906-1963

Item PartTypeName:

CIRCUIT BREAKER

5925009061963P
CIICHCCESDPMICCriticalityENAC
A
Part NumberISCRNVCRNCCHCCMSDSSADC
50939123

Characteristics Data of NSN 5925-00-906-1963, 5925009061963

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.375 INCHES NOMINAL
ADAQBODY LENGTH1.562 INCHES MAXIMUM
ADATBODY WIDTH1.281 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.875 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.625 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.700 INCHES MAXIMUM
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES DC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS50.0 DC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS300.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 DC SECOND LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.375 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.200 MINIMUM AT 200 PCT AND 8.000 MAXIMUM AT 200 PCT FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
FREQFREQUENCY IN HERTZ60.0 FIRST LOCATION
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITY4 WIRE HOOK

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC Y
Classification Control U
MGMT_CTL 9b-----
Quantity per pack No qup
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small