Are you looking quote for part 6389? The Daco Instrument Co-manufactured component (CAGE Code: 98831) is documented under NSN 6105-01-120-7916 as Motor Direct Curren. For the fastest quote, please complete our RFQ form with details about 6389. We guarantee a response within 15 minutes.
ASAP Components provides the verified 6389, classified under INC 16350, FSG 61 Electric Wire and Power and Distribution Equipment, FSC 6105 Motors Electrical, NIIN 01-120-7916, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6105-01-120-7916 Item PartTypeName: MOTOR,DIRECT CURRENT | 6105 | 011207916 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 005-960 | C | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJT | OVERALL HEIGHT | 0.525 INCHES |
| AAJU | OVERALL LENGTH | 0.970 INCHES |
| AAJV | OVERALL WIDTH | 0.845 INCHES |
| AKCT | SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ANPZ | ENCLOSURE FEATURE | TOTALLY INCLOSED |
| AXCP | WINDING TYPE | SERIES WOUND |
| AXGY | MOUNTING METHOD | FLANGE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| BFMF | COOLING METHOD | AMBIENT AIR |
| BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
| CBBL | FEATURES PROVIDED | FRAME ELECTRICALLY GROUNDED AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
| CNXS | POWER RATING | 9.0 WATTS OUTPUT |
| CWCS | LENGTH OF SHAFT FROM HOUSING | 0.220 INCHES SINGLE END |
| CWDY | TEMP RATING | -65.0 OPERATING DEG CELSIUS AND 100.0 OPERATING DEG CELSIUS |
| CWFQ | MOUNTING FACILITY CIRCLE DIAMETER | 0.660 INCHES |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 15.0 LINE TO NEUTRAL SINGLE INPUT |
| CWHZ | SHAFT END CHARACTERISTIC | A23 SINGLE STYLE SINGLE END |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9---n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 062120 - Generators/motors/parts noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 593 - Motors and parts, (machinery and parts),(less than 35 feet) |