Are you looking quote for part 675DH959? The Custom Control Sensors Inc-manufactured component (CAGE Code: 09049) is documented under NSN 5930-01-049-0713 as Switch Pressure. For the fastest quote, please complete our RFQ form with details about 675DH959. We guarantee a response within 15 minutes
ASAP Components provides the verified 675DH959, classified under INC 00206, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-049-0713, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-049-0713 Item PartTypeName: SWITCH,PRESSURE | 5930 | 010490713 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
13220E8074-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 3B ALL THREADED STUD |
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION |
AASA | THREAD LENGTH | 0.560 INCHES NOMINAL ALL THREADED STUD |
ABHP | OVERALL LENGTH | 4.400 INCHES MAXIMUM |
ABKV | OUTSIDE DIAMETER | 0.250 INCHES NOMINAL SINGLE CONNECTION |
ADAQ | BODY LENGTH | 3.520 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 5.000 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 4.600 INCHES NOMINAL |
AXGY | MOUNTING METHOD | THREADED STUD |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT AND HERMETICALLY SEALED CASE |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE PRESSURE CONNECTION |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED STUD |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJB | PROOF PRESSURE | 15.00 POUNDS PER SQUARE INCH |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES ALL THREADED STUD |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | CONNECTOR,RECEPTACLE |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 200.0 MILLIAMPERES RESISTIVE LOAD FIFTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 400.0 MILLIAMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE,PRESET AND ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | 1.50 TO 30.00 ACTUATION POINT INCHES OF WATER AND 0.50 TO 27.00 DEACTUATION POINT INCHES OF WATER |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
CTYX | CONTACT STIMULUS RATING | 19.50 ACTUATION POINT NOMINAL INCHES OF WATER AND 15.50 DEACTUATION POINT NOMINAL INCHES OF WATER AND 4.00 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN,THREADED EXTERNAL SINGLE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
THSD | THREAD SERIES DESIGNATOR | UNF ALL THREADED STUD |
End Use : 20005 | Electric apparatus |
---|---|
Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | U - Precious metal content is unknown |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | Q2200x- |
Quantity per pack | 1 |
Repariability | Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. refer to appropriate manuals or directives for specific instructions. |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | P - 77.5 |
NMFC: | 061300 - Circuit breaker/switch noi |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 658 - Electrical appliances, small |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |