| MRC | Criteria | Characteristic |
|---|
| AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 600.0 |
| AAQL | BODY STYLE | BARRIER TYPE |
| AAQW | MOUNTING SLOT LENGTH | 0.310 INCHES |
| AAQX | MOUNTING SLOT WIDTH | 0.210 INCHES |
| ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.562 INCHES |
| ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
| ABDB | TERMINAL FACILITY QUANTITY | 3 |
| ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES |
| ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.330 INCHES |
| ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.215 INCHES |
| ABGN | BOARD OVERALL LENGTH | 2.680 INCHES |
| ABGP | BOARD OVERALL WIDTH | 0.870 INCHES |
| ABGQ | BOARD OVERALL HEIGHT | 1.050 INCHES |
| ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.570 INCHES |
| ABGS | BASE THICKNESS | 1.050 INCHES |
| AGAV | END ITEM IDENTIFICATION | VIRGINIA CLASS SUBMARINE, SSN-774 |
| AMPS | CURRENT RATING IN AMPS | 50.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
| CQCW | FEEDTHRU CONNECTION END TYPE | 857 BOTH ENDS SINGLE COMBINATION |
| CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SECOND |
| CRNL | NONFEEDTHRU TERMINAL TYPE | 857 FIRST |
| CRZR | FEEDTHRU TERMINAL QUANTITY | 3 SINGLE COMBINATION |
| CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 FIRST |
| CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 SECOND |
| CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
| CWLN | TERMINAL DESIGN | FEEDTHRU |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES B4000 SINGLE ROW TERMINAL BLOCKS |
| FEAT | SPECIAL FEATURES | TERMINAL TOP: NUMBER 10 SCREW, TERMINAL BOTTOM: NUMBER 8 SCREW, WIRE RANGE CU: 10-16 AWG |
| MATT | MATERIAL | PLASTIC BOARD |
| AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 600.0 |
| AAQL | BODY STYLE | BARRIER TYPE |
| AAQW | MOUNTING SLOT LENGTH | 0.310 INCHES |
| AAQX | MOUNTING SLOT WIDTH | 0.210 INCHES |
| ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.562 INCHES |
| ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
| ABDB | TERMINAL FACILITY QUANTITY | 3 |
| ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES |
| ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.330 INCHES |
| ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.215 INCHES |
| ABGN | BOARD OVERALL LENGTH | 2.680 INCHES |
| ABGP | BOARD OVERALL WIDTH | 0.870 INCHES |
| ABGQ | BOARD OVERALL HEIGHT | 1.050 INCHES |
| ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.570 INCHES |
| ABGS | BASE THICKNESS | 1.050 INCHES |
| AGAV | END ITEM IDENTIFICATION | VIRGINIA CLASS SUBMARINE, SSN-774 |
| AMPS | CURRENT RATING IN AMPS | 50.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
| CQCW | FEEDTHRU CONNECTION END TYPE | 857 BOTH ENDS SINGLE COMBINATION |
| CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SECOND |
| CRNL | NONFEEDTHRU TERMINAL TYPE | 857 FIRST |
| CRZR | FEEDTHRU TERMINAL QUANTITY | 3 SINGLE COMBINATION |
| CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 FIRST |
| CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 SECOND |
| CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
| CWLN | TERMINAL DESIGN | FEEDTHRU |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES B4000 SINGLE ROW TERMINAL BLOCKS |
| FEAT | SPECIAL FEATURES | TERMINAL TOP: NUMBER 10 SCREW, TERMINAL BOTTOM: NUMBER 8 SCREW, WIRE RANGE CU: 10-16 AWG |
| MATT | MATERIAL | PLASTIC BOARD |