Are you looking quote for part 1110-VH-MSB? The Brooks Instrument Llc-manufactured component (CAGE Code: 4ZW64) is documented under NSN 6680-00-057-4254 as Meter Flow Rate Ind. For the fastest quote, please complete our RFQ form with details about 1110-VH-MSB. We guarantee a response within 15 minutes.
ASAP Components provides the verified 1110-VH-MSB, classified under INC 38346, FSG 66 Instruments and Laboratory Equipment, FSC 6680 Liquid And Gas Flow Liquid Level And Mechanical Motion Measuring Instruments, NIIN 00-057-4254, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| AXGY | Mounting Method | FLUSH PANEL |
| APSJ | Scale Quantity | 1 |
| ARTH | Outlet Connection Type | THREADED |
| AHZU | Integral Relief Valve | NOT INCLUDED |
| BJDM | Float Material | STEEL |
| ATEQ | Scale Type | MILLIMETER REFERENCE READING |
| AWAE | Float Quantity | 1 |
| AWGJ | Tube Material | GLASS |
| ACQW | Inlet Connection Type | THREADED |
| ABHP | Overall Length | 22.000 INCHES NOMINAL |
| BMHW | Guide Type | BEADED TUBE |
| CPZD | Inlet Connection Size | 0.750 IN. NPT |
| CPZG | Maximum Water Capacity In Gallons Per Minute | 4.04 |
| CPZM | Spinning Float | NOT INCLUDED |
| CPZP | Inlet Connection Position For Which Designed | HORIZONTAL |
| CPZS | Outlet Connection Device Type | STATIONARY |
| CPZJ | Dial Scale Smallest Increment | 2MM |
| CPZK | Dial Scale Reference Pointer | NOT INCLUDED |
| CPZQ | Inlet Connection Device Type | STATIONARY |
| CPZR | Outlet Connection Position For Which Designed | HORIZONTAL |
| BNHN | Integral Heat Source | NOT INCLUDED |
| BPHD | Maximum Working Pressure | 240.0 POUNDS PER SQUARE INCH |
| AXQG | Carrying Handle | NOT INCLUDED |
| BHBY | Dial Scale Marking Range | 0 |
| MRC | Decoded Requirement | Clear Text Reply |
| BHCM | Outlet Connection Size | 0.750 IN. NPT |
| APGF | Design Type | CASE |
| BHJT | Base | NOT INCLUDED |
| ARQS | Construction | SIDE PLATE |
| BHSQ | Float Type | GUIDED |
| ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY SERIAL NO. 6203-33610/3 |
| CPZF | Metering Tube Quantity | 1 |
| CPZN | Integral Pulsation Dampener | NOT INCLUDED |
| CPZT | Alarm Signal | NOT INCLUDED |
| ANTH | Meter Type | FLOAT |
| APQB | Unit Type | MOUNTED |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Y |
|---|---|
| Classification Control | U |
| MGMT_CTL | ------- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | B - Construction materials: includes paint and related materials, prefabricated building, wood products, metal and composition mater |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 136800 - Flow, noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 657 - Instruments, electric meter |