Are you looking quote for part SURVEYOR-50A-ANDEWGM? The Bicron International-manufactured component (CAGE Code: H0D95) is documented under NSN 6665-01-242-3408 as Detector Radiac. For the fastest quote, please complete our RFQ form with details about SURVEYOR-50A-ANDEWGM. We guarantee a response within 15 minutes.
ASAP Components provides the verified SURVEYOR-50A-ANDEWGM, classified under INC 00089, FSG 66 Instruments and Laboratory Equipment, FSC 6665 Hazard Detecting Instruments And Apparatus, NIIN 01-242-3408, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| FTLD | Functional Description | GENERAL PURPOSE ERGONOMIC COUNT RATE METER FOR DETECTION OF LOW ENERGY BETA AND HIGH ENERGY ALPHA |
| RDAL | Reference Data And Literature | MFR PT LIST 1002917 |
| AMRM | Radiation Type And Function | ALPHA RAYS MEASURES |
| AMRX | Detecting Element Type | ANY ACCEPTABLE |
| AMRZ | Detecting Element Detachability | DETACHABLE |
| ABKW | Overall Height | 4.250 INCHES NOMINAL |
| AMRM | Radiation Type And Function | BETA RAYS MEASURES |
| AMRP | Radiation Energy Rating | 0.5 MILLIROENTGENS PER HOUR MINIMUM AND 50.0 MILLIROENTGENS PER HOUR MAXIMUM |
| AMSN | Connector | INCLUDED |
| AMSE | Voltage Rating | 9.0 VOLTS NOMINAL |
| AMSM | Photomultiplier | NOT INCLUDED |
| MRC | Decoded Requirement | Clear Text Reply |
| ABMK | Overall Width | 6.797 INCHES NOMINAL |
| AMRM | Radiation Type And Function | GAMMA RAYS MEASURES |
| ADTV | Case Material | METAL |
| AMSL | Preamplifier | NOT INCLUDED |
| ABHP | Overall Length | 8.000 INCHES NOMINAL |
| ALCD | Usage Design | PORTABLE SURVEY METER 50 W/ EWGM PROBE OPTIONS A,B,H AND SJ |
| ALLB | Cable Length | 36.000 INCHES NOMINAL |
| APPF | Cable | INCLUDED |
| End Use : 21610 | Medicinal equipment |
|---|---|
| Schedule B : 9030100000 (NAICS 334519) | Instruments and apparatus for measuring or detecting ionizing radiations |
| SITC : 87471 | Instruments and apparatus for measuring or detecting ionizing radiations |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |