Quote for 86 SET AT-20 DEG F Athena Controls Inc Part with NSN 5930-01-287-5595

Part Number:  86 SET AT-20 DEG F
Alternate P/N:  86SETAT20DEGF
Manufacturer:  athena controls inc
NIIN:  12875595
Item Name :  switch thermostatic
CAGE Code:  61166
FSC:  5930 Switches
INC Code:  00451
Country:  USA
NCB Code:  01
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  02-28-2026

Are you looking quote for part 86 SET AT-20 DEG F? The Athena Controls Inc-manufactured component (CAGE Code: 61166) is documented under NSN 5930-01-287-5595 as Switch Thermostatic. For the fastest quote, please complete our RFQ form with details about 86 SET AT-20 DEG F. We guarantee a response within 15 minutes.

ASAP Components provides the verified 86 SET AT-20 DEG F, classified under INC 00451, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-287-5595, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 86 SET AT-20 DEG F

“*” Required Fields Are Compulsory

NSN Information for Part Number 86 SET AT-20 DEG F with NSN 5930-01-287-5595, 5930012875595

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5930-01-287-5595

Item PartTypeName:

SWITCH,THERMOSTATIC

59300128755950P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
86 (SET AT-20 DEG F)515

Characteristics Data of NSN 5930-01-287-5595, 5930012875595

MRCCriteriaCharacteristic
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERS5.625 INCHES NOMINAL
AGAVEND ITEM IDENTIFICATION500 GALLON LIQUID OXYGEN STORAGE AND CHARGING SYSTEM
AXGYMOUNTING METHODBASE AND SLOT
CQYJMOUNTING FACILITY PATTERNTWO POSITION IN-LINE
CSCFTERMINAL TYPESCREW
CTYCCONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE,PRESET
CTYXCONTACT STIMULUS RATING-20.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT

Schedule B & Trade

End Use : 21160 Measuring, testing, control instruments
Schedule B : 9032100000 (NAICS 334512) Thermostats
SITC : 87461 Thermostats

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC A - Item does not contain precious metal.

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL 9b-----
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top