Are you looking quote for part PHX-424? The Arnold Magnetics Corporation-manufactured component (CAGE Code: 04879) is documented under NSN 6130-01-081-2715 as Power Supply. For the fastest quote, please complete our RFQ form with details about PHX-424. We guarantee a response within 15 minutes.
ASAP Components provides the verified PHX-424, classified under INC 00740, FSG 61 Electric Wire and Power and Distribution Equipment, FSC 6130 Converters Electrical Nonrotating, NIIN 01-081-2715, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-081-2715 Item PartTypeName: POWER SUPPLY | 6130 | 010812715 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| PHX-424 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 7.000 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 3.125 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.625 INCHES MAXIMUM |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 108.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL AND 18.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| AYNH | OPERATING AMBIENT TEMP RANGE | -30.0 TO 85.0 DEG CELSIUS |
| CBBL | FEATURES PROVIDED | FILTER |
| FEAT | SPECIAL FEATURES | USED FOR AC-DC CONVERTER; 3.900 LB UNPACKAGED UNIT WT |
| End Use : 20000 | Generators, accessories |
|---|---|
| Schedule B : 8504900080 (NAICS 334419) | Static converter & inductor parts, nesoi |
| SITC : 77129 | Parts of electric power machinery (other than rotating electric power generating machinery and equipment), and parts thereof |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | U - Precious metal content is unknown |