Are you looking quote for part CND738D? The Alnor Instrument Company-manufactured component (CAGE Code: 01518) is documented under NSN 6685-01-136-5670 as Thermocouple Contac. For the fastest quote, please complete our RFQ form with details about CND738D. We guarantee a response within 15 minutes.
ASAP Components provides the verified CND738D, classified under INC 07118, FSG 66 Instruments and Laboratory Equipment, FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, NIIN 01-136-5670, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| TTQY | Terminal Type And Quantity | 4 INSULATED WIRE LEAD W/TERMINAL LUG |
| AFGA | Operating Temp Range | +400.0/+1200.0 DEG FAHRENHEIT |
| MRC | Decoded Requirement | Clear Text Reply |
| APQB | Unit Type | PROTECTIVE TUBE |
| MATT | Material | STEEL COMP 304 PROTECTIVE TUBECOPPER ALLOY THERMOCOUPLE WIRE AND IRON THERMOCOUPLE WIRE |
| AXNX | Accommodated Wire Awg Size | 18 |
| AGAV | End Item Identification | FAIRBANKS MORSE MODEL 38D8-1/8 EIGHT CYLINDER DIESEL ENGINE ABOARD 140 FT WTGB COAST GUARD VESSELS |
| FEAT | Special Features | FLEXIBLE-DETACHABLE,DUAL ELEMENT FOUR LEAD THERMOCOUPLE WITH A 12.375 INCH LONG BY .375 INCHES IN DIAMETER INSERTION TUBE WITH A .500 INCH FNPT THREADED CONNECTION; ITEM HAS A 90 DEGREE BEND RIGED TUBE WITH 18.375 INCHES OF FLEXIBLE CABLE |
| AXHR | Mounting Facility Type And Quantity | 1 EXTERNAL PIPE CONNECTION |
| End Use : 21600 | Laboratory testing instruments |
|---|---|
| Schedule B : 9027502000 (NAICS 334516) | Thermal analysis instruments and apparatus |
| SITC : 87445 | Instruments and apparatus using optical radiations (ultraviolet, visible, infrared), n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | S-09--- |
| Quantity per pack | 1 |
| Repariability | If condemned or economically unserviceable, dispose by theoperator/crew |
| Shelf Life | N/A |
| SOS | Znc |
| Unit of Measure | Ea |