Are you looking quote for part IELXK1-1-51-25.0-A3-V? The Airpax Electronics Inc-manufactured component (CAGE Code: 6Y107) is documented under NSN 5925-01-589-1625 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about IELXK1-1-51-25.0-A3-V. We guarantee a response within 15 minutes.
ASAP Components provides the verified IELXK1-1-51-25.0-A3-V, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-589-1625, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-589-1625 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015891625 | P | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| IELXK1-1-51-25.0-A3-V | 5 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.200 MAXIMUM AT 200 PCT SINGLE LOCATION |
| AKPX | Pole Quantity | 1 |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC SINGLE LOCATION |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
| ADAT | Body Width | 0.750 INCHES NOMINAL |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
| CPRT | Manual Actuator Type And Quantity | ROCKER, 1 |
| CPRW | Actuator Function | TRIP-RESET |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| AAQL | Body Style | |
| ADTV | Case Material | PLASTIC |
| AJWX | Mounting Surface To Terminal End Distance | 2.249 INCHES NOMINAL |
| ADAQ | Body Length | 1.859 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES DC SINGLE LOCATION |
| CPRQ | Reset Method | MANUAL |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |